3-26
3745 All Models & 3746-900: CIG
Select the ARC cable that has a label that corresponds to the line
needs:
ITU-T interface type
Destination (DTE or DCE)
Length
Step
5
Label an ARC cable
a. Verify that the following information about each ARC from the
plugging sheets is on a pair of ARC cable labels (part number
63F2505):
LCB:
– Number
– Location
IBM 3746-900 name
Range of the LIC 11 addresses.
Connector slot position (+0 to +14 or +16 to +30)
Symbolic line name.
b. Stick these labels at each end of the ARC cable (see 5 in
Figure 3-10 on page 3-15). Be sure to remove any old labels first.
Step
6
Connect the ARC cable to the DTE or DCE
If you are using an ARC V.24, V.35, or X.21, plug its cable interface
connector into the DTE or DCE connector and tighten the retaining
screws.
Note: If you are making a V.35 connection to a French modem or
terminal, refer to the third and fourth bullets of this step.
If you are using an ARC cable that has a 3745 connector, plug it
into the connector of the 3745-type cable:
a. Place the connecting seal on one of the connectors.
b. Hold a connector in each hand.
c. Ensure that the pins are correctly aligned with the holes in the
female connector. Push the two connectors strongly together.
d. When the side levers click into place, you have correctly
installed the connectors.