Unplugging or Plugging In a High-Speed Scanner (HSS) Cable
Step
Step
2-8
3745 All Models & 3746-900: CIG
3
Plugging in TRA cable(s)
Repeat this step for every TRA cable to be plugged in.
Note:
Make sure that all the cables are correctly labeled at both ends
before doing this step.
a. Refer to the figures of the Step 2 on page 2-7.
b. Locate the cable by the port number written on the label.
c. Touch the electrostatic discharge plate.
d. Remove the protective cap from the cable plug.
e. Plug in the new TRA cable by squeezing the levers and pushing the
cable into place until it clicks.
4
Upgrade CDF
You must perform the Upgrade procedure in "Upgrading or Updating
CDF" on page 5-7. You can either do it now and continue with the next
step or later when you have finished all your the connection procedures.
5
Activating lines
Ask the host operator to activate any lines that were plugged in.
Note: The line number is the same as the port number.
6
You have finished this procedure
If you have no other connection procedures to do, close and lock the
door using the special door key.
1
Starting
Before beginning you must first do the procedure "Getting Started" on
page 2-2.
If you are only plugging in HSS cables, go to Step 3 on page 2-9.
Otherwise continue with the next step.
2
Unplugging an HSS cable
Remove the cable by squeezing the levers and pulling out the plug.
Repeat this step for every HSS cable to be unplugged.
If you are not plugging in an HSS cable, go to Step 4 on page 2-9.
Otherwise, continue with the next step.
J1
J2
J1
J2
1029 1028
1031 1030