The operator has an integrated heater that is thermostatically controlled. Activate this
feature when the operator is used in application temperatures down to -20°F (-29°C).
To set the heater to turn on at the Close Limit:
1. Use the "Diagnose" button to scroll through the LCD
Display to "HEATER CLS"
2. Press and hold the "Stop" button on the Control Board.
3. Press and release the "Diagnose" button to turn this
feature ON and OFF.
To set the heater to turn on at the Open Limit:
1. Use the "Diagnose" button to scroll through the LCD
Display to "HEATER OPN"
2. Perform steps 2-3 as described above.
Viking Lock Mode
Turning this feature ON will secure the gate at the closed position, preventing unauthorized
! IMPORTANT:
manual entry.
Use the LCD Display to activate this feature.
1. Use the "Diagnose" button to scroll through the LCD menu to "LOCK MOD"
2. Press and hold the "Stop" button on the Control Board.
3. Press and release the "Diagnose" button to turn this feature ON and OFF.
VIKING TECHNICAL SUPPORT 1.800.908.0884
CONTROL BOARD SETUP
NOTE:
to be held open for any reason, set the
HEATER ON for both limit positions.
! IMPORTANT:
used on the gate at the limit position(s)
the HEATER has been set for.
The EPS2 cable must be connected for this feature to function.
HEATER
CLS
HEATER
OPN
If the application requires the gate
A POSITIVE STOP must be
LOCK MOD
ON
ON
ON
2 5