Heater, Lock Mode - Viking G-5 Installation Instructions And Safety Information

Hide thumbs Also See for G-5:
Table of Contents

Advertisement

Viking Heater
The operator has an integrated heater. Activate this feature when the operator is used in
application temperatures down to -20°F (-29°C).
!
This Feature is disabled on Solar ECUs.
To set the heater to turn on at the Close Limit:
1. Use the "Diagnose" button to scroll through the LCD
Display to "HEATER CLS"
2. Press and hold the "Stop" button on the Control Board.
3. Press and release the "Diagnose" button to turn this
feature ON and OFF.
To set the heater to turn on at the Open Limit:
1. Use the "Diagnose" button to scroll through the LCD
Display to "HEATER OPN"
2. Perform steps 2-3 as described above.
Viking Lock Mode
!
Standard ECU: feature is always ON and the menu is not available on the LCD Display.
!
Solar ECU: turning this feature ON will help to secure the gate at the closed position,
preventing unauthorized manual entry but may consume battery power during high wind
conditions.
Use the LCD Display to activate this feature.
1. Use the "Diagnose" button to scroll through the LCD menu to "LOCK MOD"
2. Press and hold the "Stop" button on the Control Board.
3. Press and release the "Diagnose" button to turn this feature ON and OFF.
VIKING TECHNICAL SUPPORT 1.800.908.0884
CONTROL BOARD SETUP
HEATER
CLS
HEATER
OPN
NOTE:
If the application requires the gate
to be held open for any reason, set the
HEATER ON for both limit positions.
! IMPORTANT:
used on the gate at the limit position(s)
the HEATER has been set for.
LOCK MOD
ON
ON
ON
A POSITIVE STOP must be