Unimog U500 Mounting Manuallines page 222

Body & implement
Table of Contents

Advertisement

Body and Implement Mounting Guidelines U500 North America
Minimum Wire Gage Size
12
10
8
30
4.0
6.5 10.5 16.5 26.5 42.5
35
3.5
5.5
9.0 14.0 22.5 36.5 46.0
40
3.0
5.0
7.5 12.5 20.0 31.5 40.0 50.5
45
2.5
4.0
7.0 11.0 17.5 28.0 35.5 45.0 57.0
2.5
4.0
6.0 10.0 16.0 25.5 32.0 40.5 51.0
50
Wire length in feet
Table 7.4: Minimum wire gage size
Note:
1. Find amp load on wire in left column.
2. Read to right and find wire length (in feet) equal to or
greater than circuit being installed.
3. Read up to find Minimum Wire Gage needed for circuit.
4. Both the positive and ground cable MUST be the same
size.
5. If higher loads are desired, please contact the Unimog
Implement Manager listed at the beginning of this guide-
line.
August 2005
6
4
2
1
1/0
2/0
1
Battery master switch
2
Customer installed battery positive terminal point
3
Fuses
4
Customer installed battery ground terminal point
Connect to terminal 15 (ignition) at central connection location or
5
switch. Should be fused!
6
Relays
7
Customer installed master fuse
Figure 7.4: Wiring of accessory electrical devices