Applying the Filter
When the filter design is finished, you must tell the router where to apply the filter. Apply it as a
Call Filter in the remote node that reaches your DNS server(s) (usually your ISP node). Go to
Menu 11.1, Remote Node Profile, and toggle "Edit Filter Sets" to Yes by using the spacebar.
This brings up Menu 11.5 - Remote Node Filter. Enter the number of the filter under "Call Filter
Sets" protocol filters as shown in
four by entering their numbers separated by commas.
Figure 9-8
shows the Remote Node Filter menu.
Figure 9-8.
Menu 11.5 - Remote Node Filters Menu
Press [Enter] to save this menu. Proceed back to the bottom of Menu 11.1, Remote Node Profile,
and press [Enter] to save all the changes. When you finish, restart the router.
Note: After editing and saving a submenu of Menu 11.1, you must also save Menu 11.1
or the submenu changes are discarded.
9-14
Figure
9-8. If you have multiple filters, you can cascade up to
Menu 11.5 - Remote Node Filter
Input Filter Sets:
protocol filters=
device filters=
Output Filter Sets:
protocol filters=
device filters=
Call Filter Sets:
protocol filters= 1
device filters=
Press ENTER to Confirm or ESC to Cancel:
Configuring Filters