Chapter 3: FRU Removal and Replacement Procedures
Replacing the Node
164
PCIe slot 2 (see
Replacing an Expansion Card in Riser 1
page 118).
Note: You do not need to remove any other expansion cards from
the failed Node. All other required expansion cards are pre-
installed in the replacement Node.
Installing a Replacement Node
To install the replacement DXi6900 G1 Node:
1 Install the hard drives from the failed Node in the correct locations
in the replacement Node (see
page 90).
must
Caution: You
If the hard drive locations are not correct, the system
will not function.
2 If applicable, install the optional dual port 10 GbE card (along with
any associated SFPs) or optional quad port 1 GbE card in PCIe slot 2
in the replacement Node (see
on page 118).
3 Install the replacement Node in the rack (see
the
Node).
4 Turn on the system (see
on page 23).
5 If Data-at-Rest Encryption is enabled, configure the PERC H710
integrated storage controller for encryption (see
Rest Encryption on a Replacement Integrated Storage Controller
page 128).
6 Run Factory Detect Hardware from the Service Menu to detect the
new hardware (see
7 Install the original system serial number on the new Node:
Note: The system serial number is located on the label holder
affixed to the upper right corner of the rear of the Node.
The system serial number includes the letters BVT.
Replacing a Node Hard Drive
install each hard drive in its correct location.
Replacing an Expansion Card in Riser 1
Turning On and Shutting Down the System
Factory Detect Hardware