Delayed Egress 57-80 Series
Exit Device
Installation Instructions
10

Operating Instructions

a

Power Up Sequence

1. Both insert LEDs illuminate "red" for 2 seconds while concurrently sounding buzzer for 500ms.
2. Both insert LEDs illuminate "green" for 2 seconds (no buzzer).
3. The (4) diagnostic LEDS on bottom of module illuminate for 2 seconds.
4. Insert LED illuminates to the switch position (armed or not armed).
b

Modes of Operation

There are three modes of operation: Armed (Delayed Egress),
Momentary Egress and Maintained Egress.
These modes are set by fully inserting a valid key and rotating it in
either a clockwise or counter-clockwise direction until there is a
click (detent). Note that a second click must be engaged in order to
set momentary egress. To remove the key, it must be returned to its
original center position.
Armed Mode
1. Apply power to the System; horn will sound for one second.
2. Both LEDs will fl ash RED, then both LEDs will fl ash GREEN.
3. Green (default) or Red LED on Electroguard™ insert will
illuminate (See DIP switch settings section 6).
4. Rail assembly is armed. Latchbolt cannot be retracted by
depressing the push rail for immediate egress. If rail is depressed
for (min.) one second, alarm will sound.
5. If any of above sequence fails to function, the unit is not armed.
See: Troubleshooting section
Momentary Egress Mode
1. Rotate key counter-clockwise to 2nd click and return key to
center position (key out).
2. Red (Default) or Green LED fl ashes on insert for a factory preset
time of 5 seconds. (For other time selections and LED color, see
Dip Switch Settings section 6). The rail assembly will disarm
itself and de-energize the external magnet for this time period
allowing for momentary egress.
3. After the factory preset time of 5 seconds, delay expires. Rail
assembly re-arms itself and the external magnet is re-energized.
4. Unit is then in Delayed Egress Mode (or Power Up State).
1-800-727-5477 • www.sargentlock.com
Copyright © 2005, 2007, 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or
in part without the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending
and/or patent www.assaabloydss.com/patents.
1st click
Delayed Egress (Armed)
2nd click
Momentary Egress
Center (key out)
Maintained (Disarmed)
Red LED
Green LED
*Depends on handing