Overriding is not supported with xGenConnect. In case a zone is faulted, one
shall bypass the zone manually before arming or verify the zone and clear the
fault. See user instructions.
Hold-up zones are not allowed to be set for bypass.
Zone isolation is not supported.
EN 50136-2 (Alarm transmission systems and equipment – Part 2:
Requirements for Supervised Premises Transceiver (SPT):
- Upon configuring alarm transmission path and remote connection details,
default user/installer keys shall be changed.

Options Affected by EN 50131 Regulations

EN 50131 Grade 2 Required settings
The following options and values are mandatory for EN 50131-1 Grade 2
regulations.
Period, 24 h for every path to meet ATS Class 2, 4 h for the IP path to meet
Class 4.
View Partitions and Control Partitions settings are identical
Buzzer silent, never
Quick set, off
Function keys, all set to None
User group options, No OP/CL reports option set to No
Inhibit, set to No for all zones with type Panic, 24H
Swinger shunt, set to Yes for all zones
ACK on keypad, set to None for all zones with type Keyswitch
Entry time, 45 s maximum
Entry alarms, Instant
Active, set to No for all schedules.
Activation, internal and external siren 90 to 900 s
Delay time, external siren 600 s maximum
Armed display, 30 s maximum
Mains reporting delay 10 to 70 s
User code required, enabled
Armed display, always
Alarm list, disabled
Inhibit includes, all allowed except engineer reset, which must be disabled
Pending alarms, enabled
Swinger shunt ≥ 3
Report restore, on ACK
Line fault, enabled per path used
Line fault delay, 0 s
Partition option to override EN50131-1 Arming Cancelation set to No
User option not to report open/close events – only with at least one CIE
(Control and Indicating Equipment) in the system
Refer to xGen Reference Guide for additional features, accessible at level 3.