Output Current Rating; Auxiliary Current And Battery Capacity - CADDX xGenConnect Installation And Programming Manual

Table of Contents

Advertisement

Product
Main description
NXG-1820
Touchscreen keypad
NXG-1830-EUR,
LCD keypad
NXG-1831-EUR
NXG-1832-EUR,
LCD keypad with
NXG-1833-EUR
integrated Mifare card
reader
NXG-208-G3
8 zone expander
NXG-208N
xGenConnect 8 zone
expander board
NXG-216N
xGenConnect 16 zone
expander board
NXG-220-G3
20 zone expander
NXG-504
4 relay output expander
NXG-508N
xGenConnect 8 relay
expander board
NXG-510
10 relay output expander
NXG-7002
4G Cellular and Wi-Fi
Router Module

Output Current Rating

Output
Combined J2 BELL+, J2 AUX+ (Smoke),
and J7 AUX+ (Outputs)
Combined J2 POS (XR Bus), and J3 POS
(NX Bus)

Auxiliary Current and Battery Capacity

xGenConnect (EMEA)
Discharge
Charge
Time
Time
NXG-4
12 h
72 h
24 h
48 h
NXG-8(E)
12 h
72 h
6
Current Consumption
(non-alarm)
100 mA typical, 40 mA in
idle mode
90 mA typical, 35 mA
minimum
130 mA typical, 40 mA
minimum
25 mA
30 mA
30 mA
30 mA
20 mA idle
70 mA 4 relays on
20 mA idle
130 mA 8 relays on
20 mA idle
160 mA 10 relays on
118 mA minimum,
138 mA average
35 VA
Transformer
500 mA max at
13.8 VDC
500 mA max at
13.8 VDC
7.2 Ah
12 Ah
Battery
Battery
460 mA
N/A
160 mA
N/A
475 mA
875 mA
40 VA
Transformer
600 mA max at
13.8 VDC
600 mA max at
13.8 VDC
18 Ah Battery
Reference
N/A
EN 50131 Grade 1 and 2
N/A
INCERT Grade 2
1200 mA
EN 50131 Grade 1 and 2
xGenConnect Installation and Programming Guide
Current
Consumption (alarm)
175 mA max with
sounder and screen on
max brightness
160 mA max.
200 mA max.
25 mA
30 mA
30 mA
30 mA
20 mA idle
70 mA 4 relays on
20 mA idle
130 mA 8 relays on
20 mA idle
160 mA 10 relays on
200 mA
55 VA
Transformer
600 mA max at
13.8 VDC
600 mA max at
13.8 VDC

Advertisement