Channel set up for push notifications is automatically performed by the
UltraSync+ app when required. The panel will assign the next available
channel and matching event list number. No configuration via the web pages
or DLX900 is required.
Programming Sequence
6. Communicator
a) Options
b) IP Config
c) Ethernet
d) Radio
e) Dial IP
f) Email
g) Remote Access
h) System Event Reporting
18. Channel Groups
18. Channel Groups
Instructions
1. Go to Channels.
2. Enter an Account Number up to 8 digits, hex values are accepted.
3. Select the Format of the communication channel, this will automatically use
the settings programmed for that Format in the Communicator menu.
4. Select the reporting device, by default Device 1 is the xGenConnect panel.
xGenConnect Installation and Programming Guide
17. Event Lists
→
5. Channels
→
6. Communicator
17. Event Lists
→
119