Additionally the damping steps 3 - 7 enable the selection
of a damping progression. This means:
not progressive:
by massive pressure changes the display does not react
faster than by small pressure changes
low progressive:
by massive pressure changes the display reacts some-
what faster than by small pressure changes.
high progressive:
by massive pressure changes the display reacts much
faster than by small pressure changes.
- To change the adjustment, scroll with the keys
<UP/DOWN> until the menu point "Damping".
- Press <OK> to activate.
- Adjust the desired damping step using the cursor keys
<RIGHT/LEFT>.
- Press <OK> to confirm.
8.6. Pressure unit
The measuring unit of the internal pressure sensor can
be changed. The following units are selectable:
Millibar
Inch water column
Inch mercury column
Pound per square inch
Millimetre mercury column
Hectopascal
For modification:
- Scroll with the cursor keys <UP/DOWN> until the menu
point "Pressure unit".
- Press <OK> to activate.
- Use the cursor keys <RIGHT/LEFT> to adjust the de-
sired unit for the pressure sensor.
- Press <OK> to confirm.
14
mbar
"H2O
"Hg
PSI
mmHg
hPa