Error messages on the display
• "heating up..."
• "steam temp. sensor"
• "NTC steam"
Errors without display message
• Steam boiler is not heating
• Steam boiler is heating against the medium.
• No milk or milk foam dispensing
Spare parts
• Steam boiler with heating unit and NTC
• Level probe
• Insulation
2/3.6.1.1 Level sensor
Technical data: level probe
Empty threshold
180 digits
Service life: level probe
Level probe
Technician instructions
Hot water boiler and steam boiler heating are only activated if the level sensor is
contacted.
Error without display message
• Level sensor does not switch, no milk or milk foam dispensing; instead, only hot
water is dispensed.
© WMF 800 / 900 / 1000 S / 1000 pro S Edition 07/2014 - KMT
The level sensor measures the
filling level of the steam boiler.
The evaluation takes place using
capacitance with a level control,
which is integrated into the controller.
Its function is not affected by an
insulating layer of chalk or similar
materials. The electrode should only
be replaced as a preventive measure
during a major inspection because the
evaluation is free of wear.
6 years, maximum 90,000 brewing cycles
Boiler water system
heating up...
level timeout
steam temp. sensor
See instructions, error messages, troubleshooting
Part 6
See instructions, error messages, troubleshooting
Part 6
T2-21