In this chapter the – test functions – and the single possibilities for live display resp. component test will be explained in detail as already mentioned in chapter 6!
10.1
Button > Test functions – upper window
1. Test functions – upper window
1. Exit - closes the window „Test functions"
2. Start – starts the live display
3. Stop – stops the live display
4. Error statistic – indicates the documented error statistic of the coffee machine
5. Play – starts the live display, same function as „Start"
6. Stop – stops the live display, same function as „Stop"
7. Labeling symbol – indicates the documented error statistic of the coffee machine,
same function as error statistic
8. Test button – starts or stops the component test
9. NTC coffee water – indicates the binary NTC value of the hot water boiler
10. NTC steam boiler – indicates the binary NTC value of the steam boiler
11. NTC external sensor – without function, not occupied
12. Motor current grinder / brewer motor – indicates the binary current value of the