2/3.5.4 Water supply assembly and valves
Steam Jet valve
Steam-Jet Ventil
Cappuccino valve
Cappuccinoventil
Brewing water valve
Brühwasserventil
Inlet valve
Zulaufventil
The hot water valve and the hot water dispenser must not be put out of operation.
The brewing valve is installed opposite to the flow direction so that the excess water
can be released when the boiler is heated without the boiler pressure climbing to
16 bar (opening pressure for the safety valve).
The release valve is opened when heating in order to discharge excess water.
The oscillating pump is connected for all dispensing operations from the boiler
(brewing, hot water dispensing, steam dispensing).
Technical data: water supply assembly and solenoid valves
Solenoid valves, general
Power supply
Rated voltage 24 V DC
Current draw
<500 mA
Brewing valve
Opening pressure for the
0.4 MPa (4 bar)
brewing valve
T2-16
In the standard configuration, there are
four valves in a quad valve bank. This
consists of a cappuccino valve, brewing
water valve, inlet valve and hot water
valve.
The release valve sits in the housing
floor.
An additional Steam Jet valve for
preheating cups is used in WMF 900,
1000 S, and 1000 pro S coffee
Hot water valve
Heißwasserventil
machines.
opposite the flow
direction!
See the the hot water boiler in chapter 2/3.5.1 and the
safety valve in chapter 2/3.5.3