Overload protection
In case the maximum current at one of the outputs or the total
maximum current of one ot the two connecting areas has been
exceeded, the decoder automatically switches off. Then, you have to
switch the decoder currentless, to eliminate the overload and to switch
on the decoder again.
Caution:
!
When connecting an in- or output to a live wire (e.g. to the power supply),
a very high current occurs suddenly. In this case, the overload protection
is ineffective, the decoder can be damaged irreparably.
Power supply
The Multi-Decoder MD-2 can either be supplied by the central unit or a
booster. In order to release the digital electric circuit it is also possible
to supply the decoder by a transformer of its own instead.