Facilities; Account Numbers / Ident Codes; Radio Site Code; Recorded Message (-03 Versions) - Cooper Scantronic HOMELINK EXTRA Installation & Programming Manual

Social alarm
Table of Contents

Advertisement

3
When open, the panel on the underside provides access to the:
Connector used by the PSION programmer.
Telephone programming socket.
Screw terminals for optional emergency button and extension
microphone/loudspeaker.
Call cancel links.
See Chapter 3 for more details.
SAFETY WARNING:
Disconnect Homelink from the telephone
network before removing the access panel.

Facilities

This section lists all of the facilities provided by Homelink. Those facilities
that can be programmed contain notes on which option(s) to use. For full
details on how to program individual options see Chapter 6 Programming.

Account Numbers / Ident Codes

Homelink can store up to four eight-digit account numbers. Each account
number is associated with one of the four telephone numbers that Homelink
can store. This means that the unit can communicate with up to four
independent monitoring services.

Radio Site Code

In certain kinds of accommodation there may be several Homelink units
close together. In order to make sure that each Homelink responds to only
one user all triggers are designed to transmit an identity code, called a "radio
site code".
You can program each Homelink to recognise two separate radio site codes:
an "Alarm Site Code" and a "Second Pendant Site Code". Whenever
Homelink receives a transmission containing the Alarm Site Code it sends
an "alarm" emergency call. If Homelink receives a transmission containing
the Second Pendant Site Code it sends a "low temperature" emergency call.
Note: You must instruct the monitoring centre to interpret a "low temperature"
emergency call as a "second pendant" call.
During installation you must:
a)
Set up a trigger with one of the radio site codes you have chosen (see
Chapter 5).
OR Make Homelink learn the site code from the trigger and store it as the
Alarm Site Code, see page 19.
b)
Set up all the other triggers to give the same Alarm Site Code.
c)
If necessary, select a separate site code for a second pendant, and
make Homelink learn it as the Second Pendant Site Code.

Recorded Message (-03 Versions)

Homelink can record a short speech message that it will play back to any