Fuel pump relay P0230 - shorted to positive / shorted to negative / open circuit.
Error cause
Shorted to positive: excessive voltage at PIN 22 of the control unit connector.
Shorted to negative: null voltage at PIN 2 of the injection relay.
The circuit is open: interruption of the circuit.
Troubleshooting
Shorted to positive:
Disconnect the injection relay (No. 35 on the electrical circuit diagram), turn the key to the
ON position and activate the relay through the diagnostics instrument.
Verify the presence of voltage between relay connector PIN 1 and 2 toward the cabling.
If no voltage is read, disconnect the control unit and verify insulation from battery positive
of the relay PIN 1 (or control unit PIN 22). Restore the cabling if necessary.
Shorted to negative:
Disconnect the injection relay (No. 35 on the electrical circuit diagram) and the control unit.
Verify ground insulation of the relay connector PIN 1 and 2 toward the cabling: if there is no
insulation, restore the cabling.
The circuit is open:
Disconnect the injection relay (No. 35 on the electrical circuit diagram) and the control unit.
Verify continuity of the cabling between the relay and control unit: Relay PIN 1 - control unit
PIN 22. Restore the cabling if necessary.
Coil
Check
A tester can be used for the check. In every case
the continuity of the primary and secondary wind-
ings must be checked. The reading in ohms does
not need to be exact but, if the windings are intact,
their continuity must be detected with the resist-
ance values indicated above.