Input Speed - Paradox Digiplex EVO48 V1.20 Installation Manual

High security and access system
Table of Contents

Advertisement

4.6.5 Alarm Types
[0400]: O
[2] & [6]
SECTION
PTION
S
[0101]
[0196]: O
ECTIONS
TO
Option Feature
Description
[5] [6]
sends the report code and activates the bell
Steady Alarm
OFF OFF
output
sends the report code and pulses the bell output
Pulsed Alarm
ON
OFF
(see Figure 14)
sends the report code, but the bell output is not
Silent Alarm
OFF
ON
activated. Partition must be disarmed.
Report Only
sends the report code. Disarming is not required.
ON
ON
4.6.6 Intellizone*
[0400]: O
[7]
SECTION
PTION
S
[0101]
[0196]: O
ECTIONS
TO
(default = 032) If an alarm condition occurs on a zone with option [7]
enabled, the control panel triggers the Intellizone Delay. Fire Zones cannot
be set as Intellizones. An alarm will only be generated if the selected
conditions occur during the Intellizone Delay:
1.
An alarm occurs on another zone defined as Intellizone.
2.
The zone in alarm restores and reoccurs.
3.
The zone stays in alarm for the entire Intellizone Delay.
Key in the desired 3-digit delay value (010 to 255 seconds, default value is
32 seconds) into the section corresponding to the desired partition
Any value less than 10 seconds will be replaced by the default
value of 32 seconds.
Partition 1: [3110] Partition 3: [3310] Partition 5: [3510] Partition 7: [3710]
Partition 2: [3210] Partition 4: [3410] Partition 6: [3610] Partition 8: [3810]
* UL Note: For UL Listed systems, the detection pattern of both zones must
be installed so that each zone has the capability of protecting the area alone.
4.6.7 Intellizone Options
Use these options to enable or disable different Intellizone related options.
Partition 1: [3126] Partition 3: [3326] Partition 5: [3526] Partition 7: [3726]
Partition 2: [3226] Partition 4: [3426] Partition 6: [3626] Partition 8: [3826]
Option Description
Intellizone Delay (default = disabled)
[1]
The zone stays in alarm for the entire Intellizone Delay.
Intellizone Double Knockout and Zone Crossing (default =
disabled)
[2]
The zone in alarm restores and reoccurs or an alarm occurs on
another zone defined as Intellizone
Intellizone Zone Crossing (default = disabled)
[3]
An alarm occurs on another zone defined as Intellizone.
Police Code is Generated on Zone Crossing Only (default =
[5]
disabled)
12 Reference & Installation Manual
[5] & [6]
PTIONS
[7]
PTION
Figure 14: Delayed 24Hr Fire Zone
Delayed Fire Zone
Triggered
Activate bell/siren output & delay
report transmission for 30s.
Has the zone
closed within
30s?
No
Has a 2
Delayed Fire
Zone opened
in 30s?
No
Any key on
keypad
pressed
within 30s?
Yes
Bell/siren silenced. Delay report
transmission an additional 90s.
No
Problem
corrected?
Yes
END
Alarm Disabled
4.6.8 Delay Before Alarm Transmission
[0400]: O
[8]
SECTION
PTION
S
[0101]
[0196]: O
ECTIONS
TO
(default = 000) When an alarm condition occurs on a zone with option [8]
enabled, the alarm will not be reported to the monitoring station until the
end of the Alarm Transmission Delay. Disarming the system cancels any
report originating from this zone. To program the Alarm Transmission Delay,
access section [3055].

4.7 Input Speed

(001 to 255 X 30msec, default = 600ms)
The Input Speed defines how quickly the control panel responds to an open
zone detected on any hardwired input terminal (does not apply to
addressable motion detectors and door contacts). Set the Input Speed (001
to 255 X 30ms, default = 600ms):
[0961]
Input 01
[0962]
Input 02
[0963]
Input 03
[0964]
Input 04
[0965]
Input 05
[0966]
Input 06
[0967]
Input 07
[0968]
Input 08
Yes
Latch alarm and transmit
nd
Yes
report code as described
in section 4.4.13
No
[8]
PTION
[0973]
Input 13 (ATZ of Input 01)
[0974]
Input 14 (ATZ of Input 02)
[0975]
Input 15 (ATZ of Input 03)
[0976]
Input 16 (ATZ of Input 04)
[0977]
Input 13 (ATZ of Input 01)
[0978]
Input 14 (ATZ of Input 02)
[0979]
Input 15 (ATZ of Input 03)
[0980]
Input 16 (ATZ of Input 04)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Digiplex evo192 v1.20

Table of Contents