Paradox Digiplex EVO48 V1.20 Installation Manual page 7

High security and access system
Table of Contents

Advertisement

Charging and battery test
LED (every 60 seconds).
12Vdc 7Ah Rechargeable
Acid/Lead or Gel Cell
Backup Battery
PGM Trigger: This Jumper
allows you to choose whether
the solid-state relay PGMs are
grounded (-) or give out 12V (+).
Bell/Siren
Bell/Siren
Connection for Self-Contained Bell/Siren
The sum of the current
drawn from the BELL and
AUX must be limited to
2.0A. Exceeding this limit will
overload the panel power supply
and lead to complete system
shutdown.
40VA transformer strongly recommended
Figure 3: EVO Control Panel Wiring Diagram
AUX LED and AUX control button.
(Activates and deactivates the auxiliary
output)
Optional on EVO48
Four pin connector
can be used for
quick installation
of a keypad or
module.
PLEASE NOTE: When powering up the EVO control panel, the panel will begin a module scan to verify if all the modules
connected to the panel are operational. The scanning process will take between 30 seconds and 3 minutes to complete
depending on the number of modules connected to the control panel. The module scan is complete when the LCD
keypad begins to show the partition status. Only after the module scan is complete will the control panel be fully
operational.
When installing the combus wires in a noisy environment, or when connecting the combus across separate buildings, you
must use a shielded cable. Refer to section 2.15.1 on page 6.
Please see UL and ULC Warnings on page 54 for applicable UL/ULC warnings and information.
VDMP3 voice module module
connects directly to the control panel via the EBUS
and DIALER connectors
Built-in RTC
(See 'VDMP3 Installation Instructions" on page 27.)
See page 7.
For the hardwired connections, see
Single Zone Input Connections on page
6 and Double Zone Connections on
page 6.
AUX Power (Auxiliary):
Provides up to 700mA. Refer to
Table 1 on page 4
Combus
Used for In-Field Firmware
Upgrade through a
307USB
Direct Connect Interface.
Red "
" LED:
STATUS
Flashing -
Indicates proper
operation.
Always On - Panel is using
a phone line.
Fast Flash - Indicates a control
panel failure.
Off -
Control panel error.
Press and hold the Reset
button for 2 seconds to restart
the panel without removing
power.
AWG#14 single
Ground
conductor solid
clamp
copper wire
Cold water
To metallic
pipe
enclosure
grounding
Door Contact
* if EOL is enabled in
the control panel
The combus supports a maximum of 127 (EVO48)
or 254 (EVO192) modules. Although external power
supplies can be used to provide power to modules
connected far from the control panel, the total
distance of all runs of wire combined cannot
exceed 914m (3000ft). For example, if ten runs of
wire measuring 305m (1000ft) each are connected
to the control panel, the total distance would be
3048m (10, 000ft), which exceeds the system's
capacity.
Before adding any module to the control panel
make sure you shutdown the AUX output by
pressing and holding the AUX button for 3
seconds.
EVO Control Panel 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Digiplex evo192 v1.20