3.1 WinLoad Uploading/Downloading Software*

We recommend programming the control panel with WinLoad. Refer to
WinLoad Software on page 38 for details.
* UL Note: Not verified by UL

3.2 Paradox Memory Key

The Paradox Memory Key can copy the programmed contents of one
control panel into as many others. Not to be used with UL Listed
systems.
Copy to Memory Key
1.
Insert the Memory Key (PMC-4) onto the control
panel's connector labelled "
2.
To copy the contents to the Memory Key except
zone numbering and sections [0501] to [0532],
enter installer programming mode, then enter
section [4020]. (Depending on the memory key, the
labels may or may not be included.)
To copy the contents to the Memory Key including
zone numbering and sections [0501] to [0532],
enter section [4021]. (Depending on the memory
key, the labels may or may not be included.)
3.
When the keypad emits a confirmation beep, remove the Memory Key.
Remove the write protect jumper.
Download to Control Panel
1) Insert the Memory Key onto the control panel's
connector labelled "
MEM KEY
2) To download the contents of the Memory Key except
zone numbering and sections [0501] to [0532], enter
installer programming mode and then enter section
[4010]. (Depending on the memory key, the labels
may or may not be included.)
To download the contents of the Memory Key
including zone numbering and sections [0501] to [0532], enter installer
programming mode and then enter section [4011].(Depending on the
memory key, the labels may or may not be included.)
3) When the keypad emits a confirmation beep, remove the Memory Key.
Figure 12: Using the Memory Key
Jumper ON =
Can copy and download
contents of the Memory Key

3.3 Module Broadcast

Keypads and other modules can also be programmed easily by using
Module Broadcast (see section 13.16 on page 31). Once a module is
programmed, its sections can be sent to other similar modules through the
combus.
8 Reference & Installation Manual

Programming Methods

3
".
MEM KEY
".
Jumper OFF =
Cannot override contents
of the Memory Key

3.4 Programming Through a Keypad

Use the "EVO Programming Guide" to record how the sections were
programmed. To enter programming mode:
1.
Press and hold the [0] key.
2.
Key in the [
INSTALLER CODE
3.
Key in the 4-digit [
SECTION
4.
Key in required [
]. Refer to the "EVO Programming Guide" or to
DATA
the corresponding sections in this manual.
For LCD Keypads: The control panel will save the data and go to the next
section or press the [
] key to save the data and go to the next
ENTER
section. Press the [
] key go to the preceding step or to erase the
CLEAR
current data entry.
For Grafica Keypads: Press Grafica's center action key (Save) to save the
data and go to the next section. Press the right action key (Exit) to go to the
preceding step or press the left action key (Clear) to erase the current data.
3.4.1 Feature Select Programming
Most of the options are programmed using the Feature Select Method.
For LCD Keypads: The option is considered ON when the number
appears within the brackets on the LCD keypad. Turn options ON and OFF
by pressing the corresponding keys on the keypad and then press [
to save.
For Grafica Keypads: Select or clear the check boxes or set the options by
pressing the corresponding keys on the keypad. The feature is considered
ON when its check box is selected. Press the Grafica's center action key
(Save) to save.
3.4.2 Decimal Programming
Sections may require 3-digit decimal values from 000 to 255.
3.4.3 Hexadecimal Programming
Sections may require Hexadecimal values from 0 to F. Press:
For LCD Keypads:
[0] to [9]
= values 0 to 9 respectively
[
] key
= A
[
STAY
DISARM
[
] key
= B
[
FORCE
BYP
[
] key
= C
[
ARM
MEM
For Grafica Keypads:
[0] to [9]
= values 0 to 9 respectively
[#]
= A to F (press the key until the desired letter appears)

3.5 Module Programming Mode

To program a Module with a keypad, enter Module Programming Mode:
1.
Press and hold the [0] key.
2.
Key in the [
INSTALLER CODE
3.
Key in section [4003].
4.
Key in 8-digit [
SERIAL NUMBER
5.
Key in 3-digit [
] and required [
SECTION
Programming Guide" for details.
The control panel will redirect all programming to the selected module. To
exit the Module Programming Mode, press the [
keypads, or the right action key (Exit) on Grafica keypads.
] (default = 000000).
].
] key
= D
] key
= E
] key
= F
] (default = 000000).
] of the module.
]. Refer to the "Module
DATA
] key on LCD
CLEAR
]
ENTER