Zone Partition Assignment; Zone Options - Paradox Digiplex EVO48 V1.20 Installation Manual

High security and access system
Table of Contents

Advertisement

4.4.8 24Hr Gas Zones*
[0400]: F
= 8
SECTION
IRST DIGIT
S
[0101]
[0196]: F
ECTIONS
TO
When a 24Hr Gas zone opens, the control panel will immediately generate
an alarm.
4.4.9 24Hr Heat Zones**
[0400]: F
= 9
SECTION
IRST DIGIT
S
[0101]
[0196]: F
ECTIONS
TO
When a 24Hr Heat zone opens, the control panel will immediately generate
an alarm.
** UL Note: UL Listed compatible devices must be used for UL systems. For
UL Listed systems, this type of zone should be programmed as a pulsing Fire
alarm.
4.4.10 24Hr Water Zones*
[0400]: F
= A
SECTION
IRST DIGIT
S
[0101]
[0196]: F
ECTIONS
TO
When a 24Hr Water zone opens, the control panel will immediately
generate an alarm.
4.4.11 24Hr Freeze Zones*
[0400]: F
= B
SECTION
IRST DIGIT
S
[0101]
[0196]: F
ECTIONS
TO
When a 24Hr Freeze zone opens, the control panel will immediately
generate an alarm.
* UL Note: UL Listed compatible devices must be used for UL systems. For UL
Listed systems, this type of zone must be programmed as a silent auxiliary
alarm.
4.4.12 Delayed 24Hr Fire Zone
[0400]: F
= C
SECTION
IRST DIGIT
S
[0101]
[0196]: F
ECTIONS
TO
The Delayed 24Hr Fire Zone definition from Figure 14 on page 12 is used in
homes where a smoke detector often generates false alarms. A zone
programmed as Fire becomes normally open and requires an EOL resistor.
The keypads must be assigned to the same partition as the Delayed 24Hr Fire zone
for the buzzer to activate.
* UL Warning: For UL/ULC installations, a Fire zone cannot be bypassed and its
alarm type must be Pulsed (audible).
4.4.13 Standard 24Hr Fire Zone
[0400]: F
= D
SECTION
IRST DIGIT
S
[0101]
[0196]: F
ECTIONS
TO
A zone programmed as Fire becomes normally open and requires an EOL
resistor. When a Standard 24Hr Fire Zone triggers, the control panel can:
• send a Zone Alarm report code (see section 9.2.1 on page 22).
• send a Fire Loop Trouble Report (see section 9.2.11 on page 23) if a
tamper/wiring fault occurs on a Fire Zone. A "Zone Fault Trouble" will
also appear in the keypad's Trouble Display.
• generate a Fire alarm, which can be silent, pulsed, steady or report only.
Fire alarms generate an intermittent signal (see Figure 13).
* UL Warning: For UL/ULC installations, a Fire Zone cannot be bypassed
and its alarm type must be Pulsed (audible).
Figure 13: Bell/Siren Output During Fire Alarm
= 8
IRST DIGIT
= 9
IRST DIGIT
= A
IRST DIGIT
= B
IRST DIGIT
(Not to be used with UL Listed systems)
= C
IRST DIGIT
= D
IRST DIGIT
4.4.14 Stay Delay Zone
[0400]: F
= E
SECTION
IRST DIGIT
S
[0101]
[0196]: F
ECTIONS
TO
Using the Regular or Force arming methods, the control panel processes
the zone as an Instant zone (see section 4.4.4 on page 10). Using the Stay
or Instant arming methods and the zone is triggered, the control panel will
not generate an alarm until the programmed Stay Delay elapses. A zone
defined as Stay Delay 1 follows the Entry Delay 1 Timer of its assigned
partition. A zone defined as Stay Delay 2 follows the Entry Delay 2. To
program the Entry Delay Timers, refer to Entry Delays 1 and 2 on page 10.

4.5 Zone Partition Assignment

[0400]: S
SECTION
ECOND DIGIT
S
[0101]
[0196]: S
ECTIONS
TO
Assign zones to one partition.

4.6 Zone Options

The zone options from are described below. Refer to the EVO programming
guide for additional information on Zone Programming.
4.6.1 Auto Zone Shutdown
[0400]: O
[1]
SECTION
PTION
S
[0101]
[0196]: O
ECTIONS
TO
(default = 000) When enabled, the control panel will stop generating alarms
once the Auto Zone Shutdown Limit is reached. It resets every time the
partition that is assigned to the corresponding zone is armed. To program
the Auto Zone Shutdown Limit, enter the desired 3-digit counter (000 to
015) into section corresponding to the desired partition (000 = disabled):
Partition 1: [3114]
Partition 2: [3214]
Partition 3: [3314]
Partition 4: [3414]
4.6.2 Bypass Zones
[0400]: O
[2]
SECTION
PTION
S
[0101]
[0196]: O
ECTIONS
TO
(default = enabled) Allow zones to be Manually Bypassed.
4.6.3 Stay Zones
[0400]: O
[3]
SECTION
PTION
S
[0101]
[0196]: O
ECTIONS
TO
Only zones with option [3] enabled will be bypassed when the partition is
Stay armed or Instant armed. All other zones will remain activated. Fire
Zones cannot be set as Stay Zones.
4.6.4 Force Zones
(Not to be used with UL Listed systems)
[0400]: O
[4]
SECTION
PTION
S
[0101]
[0196]: O
ECTIONS
TO
Only zones with option [4] enabled can be bypassed when the partition is
Force armed. Fire Zones cannot be Force Zones.
F
AND
= E
F
IRST DIGIT
AND
= 1
8
TO
= 1
8
ECOND DIGIT
TO
[1]
PTION
Partition 5: [3514]
Partition 6: [3614]
Partition 7: [3714]
Partition 8: [3814]
[2]
PTION
[3]
PTION
[4]
PTION
EVO Control Panel 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Digiplex evo192 v1.20

Table of Contents