3.9
Analog Output Connection
The MIC-1810 provides two AO output channels. You can use the internal precision -
5 V or -10 V reference to generate 0 to +5 V or 0 to +10 V AO output. Use an external
reference for other AO output ranges. The maximum reference input voltage is ±10 V
and maximum output scaling is ±10 V. Loading current for AO outputs should not
exceed 5 mA.
Fig. 3.12 shows how to make analog output and external reference input connections
on the MIC-1810.
MIC-1810 User Manual
Figure 3.12 Analog Output Connections
26