The Led Light Indicators - AEI HA-266 Owner's Manual

6-zone alarm control panel with auto-dialer and communicator
Table of Contents

Advertisement

INITIATE THE LISTEN-IN FUNCTION
Please put a "
" in the box showing your selected option:
LISTEN-IN ENABLED
LISTEN-IN DISABLED
6) At the end of the message, the dialer waits 3 seconds for you to acknowledge
signal is required).
Upon receipt of the acknowledgement signal, the dialer removes the
presently contacted telephone from its task list for the current event in the manner of listen-in
disabled.
7) If listen-in function is permitted
(enabled)
of time after acknowledgement.
8) At the end of the listen-in period, a short BEEP is generated. If you key in [1] again within
10 seconds, a new listen-in period begins. Without keying [1], the dialer will go
The listen-in period may be prolonged as many times as necessary or terminated the
function immediately after the short BEEP by keying in [9] from your telephone.
1 - - - - - - - - -
TO INITIATE A NEW LISTEN-IN PERIOD
9 - - - - - - - - -
TO TERMINATE THE LISTEN-IN FUNCTION IMMEDIATELY
9) The listen-in function allows you to listen to the protected premises with your telephone. The
on-board microphone of the Alarm system is enabled during the listen-in period.
70
ALARM REPORTING AND ACKNOWLEDGEMENT
SECONDS
(DEFAULT: 60 SECONDS)
OPTION
SELECTED
(An DTMF
, the dialer enables the listen-in for a preset period

THE LED LIGHT INDICATORS

INDICATORS
ZONES
(6 LEDs)
TAMPER
ZONE
(eq. to zone 8)
"1"
EXIT/ARMED
AC POWER
BATTERY
on hook
.
PROGRAM
ARM
PROHIBITED
DIALING
RECORDING
HA-266
HA-266
THE SYSTEM CONTROL CONSOLE AND ITS INDICATORS
ON
OFF
!
!
Zone unsealed
Zone sealed
(faulted)
(Normal)
Please check
the zone
connections
.
!
Alarm armed
!
Alarm disarmed
!
AC Power is
being supplied
!
!
Battery faulted
Battery normal
!
!
System in
Normal state
program mode
!
!
System in arm
System is
prohibited mode,
armed after exit
indicator is ON
delay expired
during exit delay
!
System in forced
period
to arm mode
!
Dialing in
!
No dialing is in
DTMF format
progress
!
Dialing for duress
after the duress
code is entered
!
Voice
!
No recording, or
recording is in
the recording
progress
time is expired
FLASHING
FLASHING FAST
!
Zone is or was in alarm
FLASHING FAST WITH STOPPING
INTERVAL
!
Zone is in alarm memory, system
is disarmed
FLASHING SLOW
!
Zone is isolated
!
In exit delay period
!
AC power failure
!
Flashing Alternatively with "BATTERY"
LED during Power-up Delay
!
Battery is under testing
!
Flashing Alternatively with "AC
POWER" LED during Power-up Delay
!
The system can not be armed
after exit delay expired due to
faulty zone(s) existing, see zone
indicator for the faulty zone(s)
!
Dialing in pulse format
FLASHING TWICE
!
The system is in telephone line
fault testing
7