Configuration Of The Protection Zones - AEI HA-266 Owner's Manual

6-zone alarm control panel with auto-dialer and communicator
Table of Contents

Advertisement

DISARM THE SYSTEM AND CLEAR THE ALARM MEMORY
DISARM THE SYSTEM
In the condition of there is no alarm occurred when you come back from outside.
1) Enter the premises only through a TIME DELAY door.
!
If the entry beep is enabled, the control console will sound constantly until the ENTRY
DELAY time expires, please put a "
ENTRY BEEP ENABLED
ENTRY BEEP DISABLED
2) Enter your [USER CODE] and validate by [#] key within the ENTRY DELAY time period.
USER CODE
#
!
The EXIT/ ARMED LED will go OFF and 2 beeps will be heard. The system is disarmed.
!
If wrong code is entered, 5 beeps will be generated. Enter your user code again after the
5 beeps.
DISARM THE SYSTEM AFTER AN ALARM OCCURS
Enter your [USER CODE] and validate by [#] key.
USER CODE
#
!
This will silence the siren/bell and disarm the system.
!
The ZONE LEDs on the control console will flash to help you to remember where the
violations occurred.
!
The alarm memory can be kept as long as you like before you arm the system again.
58
(DEFAULT: 30 seconds)
" in the box showing your selected option:
OPTION
(DEFAULT)
SELECTED
OPTION
SELECTED

CONFIGURATION OF THE PROTECTION ZONES

ZONE LOCATIONS
21=ZONE 1
22=ZONE 2
23=ZONE 3
24=ZONE 4
25=ZONE 5
26=ZONE 6
27=NOT USED 28=ZONE T
CODE 1--TRIGGERING MODE
0---SINGLE TRIGGER:
does not accept 2nd triggering to prevent noise pollution. The
zone will be refreshed when the system is reset.
1---MULTIPLE TRIGGER:
The zone can be re-triggered after alarm was occurred if the
system is still armed.
CODE 2--LOOP RESPONSE MODE
0---INSTANT:
The zone gives no entry delay and triggers the alarm instantly.
1---ENTRY DELAY 1:
setting on the entry delay timer 1.
2---ENTRY DELAY 2:
setting on the entry delay timer 2.
REMARK :
The purpose of entry delay 1 and entry delay 2 is to provide
operation convenience for the owner to reach the panel from
different entrances of the house to disarm the system.
For example:
requires more time than from the main door. With the help of
2 entry delays, the owner can set different entry delay times
for the two entrances.
3---24-HOUR INSTANT:
system is armed or disarmed. It gives instant alarm whenever it is
triggered.
4---24-HOUR SILENT PANIC:
matter the system is armed or disarmed. It activates the communicator
and telephone dialer but not the local alarm output
light)
whenever it is triggered. Make sure that either the dialer or the
communicator is enabled for alarm reporting, otherwise, the zone gives
no function and the zone LED will be ON showing that it is a faulty zone.
CODE 3--LOOP RESPONSE TIME
Loop response time is the time required to trigger a protection Zone.
0 -- 25 mS
1 -- 250 mS
HA-266
HA-266
ENTRY OF CODES
LOCATIONS
CODE 1
21
0
(TAMPER SWITCH)
The zone can only give alarm once. It
(DEFAULT FOR ALL ZONES)
The zone gives entry delay according to the time
The zone gives entry delay according to the time
entering the house from the garage usually
The zone is always in standby mode, no matter the
The zone is always in standby mode, no
(no siren and strobe
2 -- 500 mS
(DEFAULT FOR ALL ZONES)
3 -- 750 mS
PROGRAMMING THE PANEL
(Location: 21-28)
CODE 2
CODE 3
VALIDATION
0
0
#
DEFAULT VALUES
FOR CODE 2
CODE
ZONE
RESPONES
2
1
ENTRY DELAY 1
1
2
1
ENTRY DELAY 1
3
INSTANT
0
4
0
INSTANT
3
5
24-HR INSTANT
3
6
24-HR INSTANT
-
7
NOT USE
T
3
24-HR INSTANT
19