Setting The Exit Delay Time; Setting The Entry Delays; Setting The Siren Duration - AEI HA-266 Owner's Manual

6-zone alarm control panel with auto-dialer and communicator
Table of Contents

Advertisement

SETTING THE EXIT DELAY TIME

EXIT BEEP
0----DISABLED
1----ENABLED
(DEFAULT)
: The system beeps during the exit delay period
EXIT DELAY
(DEFAULT: 60 seconds)
2 999 SECONDS
-
The time duration can be set from 2 to 999 seconds

SETTING THE ENTRY DELAYS

ENTRY DELAY LOCATIONS
31--ENTRY DELAY 1
32--ENTRY DELAY 2
ENTRY BEEP
0---DISABLED
1---ENABLED
(DEFAULT)
:
The system beeps during the entry delay period
ENTRY DELAY
(DEFAULT: 30 seconds, ENTRY DELAY 1
60 seconds, ENTRY DELAY 2)
2 999 SECONDS
-
The time duration can be set from 2 to 999 seconds

SETTING THE SIREN DURATION

RING BACK
0----DISABLED
(DEFAULT)
1----ENABLED:
The system will activate its timing alarm output
to generate short beeps when the system is armed or disarmed:
1 BEEP-----DISARMED
2 BEEPS-----ARMED
SIREN DURATION
(DEFAULT: 300 seconds)
2 999 SECONDS
-
The siren duration can be set from 2 to 999 seconds
20
PROGRAMMING THE PANEL
(Location: 30)
ENTRY OF CODES
LOCATION
CODE 1
EXIT DELAY
30
0
2 - 999
(Location: 31-32)
ENTRY OF CODES
LOCATIONS
CODE 1 ENTRY DELAY VALIDATION
31
0
2 - 999
(Location: 33)
ENTRY OF CODES
LOCATION
CODE 1
SIREN TIME
33
0
2 - 999
(terminal 9)
Your system has been programmed for one of the following triggering mode for the people to
enter the premises, please put a "
VALIDATION
#
HANDOVER DISABLED
The system is in normal operation. All the protection zones can be triggered with their
functions according to the zone configuration settings.
HANDOVER ENABLED
In handover enabled condition, any delay zone is triggered first, all the instant zones will be
disabled during the ENTRY DELAY time period, except the 24 hour protection zones.
With this feature, you can always set the motion sensors for interior protection with the INSTANT
#
zones and the sensor for main door protection with the DELAY zone.
!
The system will always give you ENTRY DELAY when you go in the premises from the main
door entrance.
!
The system will always give INSTANT ALARM to the people who enter the premises NOT
from the main entrance, such as from the window, or any place that is protected by the
instant zone. Usually that is a thief!
VALIDATION
#
HA-266
HA-266
TRIGGERING OPTIONS
" in the box showing your selected option:
OPTION
(DEFAULT)
SELECTED
OPTION
SELECTED
57

Advertisement

Table of Contents
loading

Related Products for AEI HA-266

Table of Contents