Back-Up Battery; Connection Of Power Transformer - AEI HA-266 Owner's Manual

6-zone alarm control panel with auto-dialer and communicator
Table of Contents

Advertisement

TEST THE TELEPHONE NUMBERS IN COMMUNICATOR AND AUTO-DIALER
To ensure the alarm reporting capability of the communicator and the auto dialer of your system
in good order, it is recommended to test the telephone numbers in each of their locations one
by one by sending a current status report or the recorded message to the appropriate receiving
parties.
!
Please inform the appropriate receiving parties beforehand when you make the tests.
!
The system will refuse your test if the communicator or the auto dialer is not enabled, or no
telephone number is stored in the location that is going to be tested.
Enter your [USER CODE], press [ ], Enter the [TELEPHONE LOCATION], validate by [#]
To initiate main monitor station test --- COMMUNICATOR TELEPHONE NO.1
USER CODE
50
#
To initiate backup monitor station test --- COMMUNICATOR TELEPHONE NO.2
USER CODE
51
#
To initiate auto dialer 1st telephone test --- DIALER TELEPHONE NO.1
USER CODE
60
#
To initiate auto dialer 2nd telephone test --- DIALER TELEPHONE NO.2
USER CODE
61
#
To initiate auto dialer 3rd telephone test --- DIALER TELEPHONE NO.3
USER CODE
62
#
To initiate auto dialer 4th telephone test --- DIALER TELEPHONE NO.4
USER CODE
63
#
!
The system will generate two beeps if test is accepted.
!
The system will generate five beeps if test is refused due to function disabled or no
telephone number stored.
!
The communicator will send the current status report for monitor station testing.
!
The auto dialer will send the recorded message for telephone testing.
!
The system will only activate the telephone number that is initiated for testing. There is
nothing happened to other numbers.
!
The telephone number will dial only once in each testing even its program option in dialing
attempt is more than one.
64
TEST YOUR SYSTEM
BACK-UP BATTERY (NOT SUPPLIED)
Use a 1.2V/1.2Ah lead acid rechargeable battery for the system. Make sure the battery is
connected with correct polarity, Red to (+) and Black to ( ). The battery is always trickle
charged by the built-in charger while the system is supplied by AC power through a 14-16V DC
power adaptor.
.
F
Put the battery in the position shown in the battery compartment

CONNECTION OF POWER TRANSFORMER

AP-960 power transformer is recommended for 220-240V AC operation, which gives 12VDC
output at 1.5 Amp rated current. Power transformer is purchased separately.
!
Connect the 12VDC output voltage to terminals 6 and 7 on the board with correct polarity.
!
Wiring to the transformer must not exceed 100 feet using 16 gange wire. The voltage reading
between terminals 6 and 7 of the control must not fall bellow 14VDC at standby. Always put
the power transformer closed to the control.
!
Do not plug the transformer into AC outlet until all wiring connections to the control are
complete. As a safety precaution, always power down the control when making such
connection.
!
The power transformer can be fixed on wall with screw.
HA-266
HA-266
TERMINAL DEFINITIONS AND DESCRIPTIONS
-
Battery Connection
Wires
HA-266 Cabinet
AP-960
12-16VDC