Programming The Panel; How To Enter Programming Mode; Use The Factory Set Master Code; Use Your Own Master Code - AEI HA-266 Owner's Manual

6-zone alarm control panel with auto-dialer and communicator
Table of Contents

Advertisement

TEST YOUR SYSTEM
Please make sure that the system is in DISARMED mode when you perform the tests.
STANDBY BATTERY TESTING ROUTINES
The system can be programmed to perform dynamically and automatically test of its standby
battery with the options of periodic test and manual test.
!
The test takes 2 minutes. The
BATTERY
!
AC power is turned OFF in order to monitor the battery under load during the test.
!
Two beeps will be generated and the
!
If the battery is low or dead, five beeps will be generated, the
control console will continuously generate the warning signal of one short beep per 30
seconds until the next test.
!
A battery status report will be sent to the monitor station on the following two testing results
if the communicator is enabled:
1) The battery is
LOW
A battery
2) The battery resumes
NORMAL
but it was
No report will be given if the battery is normal in this test and it was also normal in the last
test.
NOTE:
1) The system will refuse to initiate the standby battery dynamic test in alarm condition, or, in
the condition of AC power failure, but the system will send a battery low report automatically
before battery exhausting if the battery is
2) The standby battery should be replaced every two to three years with a rechargeable 12V,
1.2Ah, lead acid battery.
TEST THE BACK-UP BATTERY -- PERIODIC
The system can be programmed with the following options for periodic testing of the back-up
battery, please put a "
" in the box showing your selected option:
DAILY (EVERY 24 HOURS) BATTERY TEST ENABLED
WEEKLY (EVERY 7 DAYS) BATTERY TEST ENABLED
PERIODIC BATTERY TEST DISABLED
!
The counting of the periodic test starts at the time when the system is power-up
or DC power is firstly connected)
.
!
The time counting of the periodic test is not affected by the manual battery test.
62
LED will flash during the test.
BATTERY
LED will be OFF if the battery is normal.
BATTERY
LED will be ON. The
LOW
report.
LOW
A battery
NORMAL
LOW
lasting for more than two minutes.
OPTION
SELECTED
OPTION
SELECTED
OPTION
SELECTED
You may program the panel from the system control console. Firstly, you are required to make
the system in programming mode, then key in the two digit
address
, followed immediately by the desired programming values
the [#] key to store the data. The console will beep twice to confirm the data is successfully
stored, and that 5 beeps will be generated for unsuccessful data entry. If you are not sure that
the correct programming values have been entered, program the programming location again.
After programming is finished, press the [ ] key twice to leave programming mode.
The maximum allowable time for each digit entry is 10 sec
ATTENTION:
Please make sure that the alarm control panel is firmly fixed to the metal box before
applying power to the system. Otherwise, the tamper switch will be triggered instantly to
give alarm and there will be no user code available for turning off the alarm before the
system is programmed.

HOW TO ENTER PROGRAMMING MODE

report.

1. USE THE FACTORY SET MASTER CODE

For the owner's convenience in programming at the first time, the factory has put a Master Code
1234 into the system. The owner can use this code for the system to enter to programming mode.
To compromise security, in all cases, the owner should program a personal Master Code to
invalidate the factory set Master Code.
!
The console will beep twice to confirm that the system is in programming mode.
!
The
PROGRAM

2. USE YOUR OWN MASTER CODE

In the case that the factory set Master Code was replaced by your own Master Code, you have
to use your personal Master Code to enter to programming mode.
(DEFAULT)
!
The console will beep twice to confirm that the system is in programming mode.
!
The
PROGRAM
(when AC
HA-266
HA-266

PROGRAMMING THE PANEL

onds.
FACTORY SET
MASTER CODE
VALIDATION
1
2
3
4
LED is ON.
MASTER CODE
VALIDATION
MASTER CODE
LED is ON.
Programming Location or the
(program data)
, then press
15