UNPLUGGABLE WIRE HARNESS

DO NOT apply power to the alarm control panel while making connections. Tape all the wire
ends of the unused wires.
1 (RED)
: This terminal provides a continuous +12V output power at normal condition
of no alarm. The +12V output is switched OFF at alarm condition. The
output is equipped with a 1.5A resettable fuse.
2 (BLACK)
:
Common Ground ( ).
-
3 (GREY)
:
This terminal provides +12V output power at alarm condition with the time
period according to the setting of the alarm timer. It is suitable for energizing
electronic siren or alarm bell. The output is equipped with a 1.5A resettable fuse.
4 (GREEN)
:
This terminal is prepared for connecting the arm-disarm remote keyswitches
(eg. Model: RKS-2M) or the wireless remote controller (e.g. Model: RPS-302M).
It accepts Normally Open (N.O.) momentary switches and is +12V
triggered. Maximum 3 remote switches can be connected in parallel.
5 (LIGHT BLUE) :
This terminal provides an unswitched +12V output power refering to the
common ground. It gives output power all the time no matter the system is
armed or disarmed. Suitable for those devices require uninterrupted p o w e r
supply. Such as smoke detectors, motion sensors, control keypads etc. This
terminal is equipped with a 750mA resettable fuse.
UTILIZE THE REMOTE KEY SWITCH FOR SYSTEM ARM-DISARM CONTROLS
ARM THE SYSTEM
KEY SWITCH
STATUS
CONTACT
!
1st Touch
Away mode arming
!
2nd Touch
Home mode arming
DISARM THE SYSTEM
!
1st Touch
System disarmed
!
Alarm memory is
2nd Touch
cleared
!
System keeps in
disarmed mode
10
TERMINAL DEFINITIONS AND DESCRIPTIONS
RESULTS
!
Exit delay starts
!
Exit beep sounds if it is enabled
!
System will be armed after exit delay expired
!
The 2nd touch must be made within the exit delay
period
!
Exit beep sounds continuously until the end of the exit
delay
!
System will be armed after exit delay expired
!
The system is disarmed and reset if there was no
alarm occurred. It is ready for re-arming
!
The system is disarmed but with alarm memory if
there was alarm occurred, 2nd touch is required
!
The alarm memory LEDs are off
(The zone LEDs on
the control console)
!
The system is ready for re-arming
DELETE A USER CODE
8 user code locations are available in the system but putting user codes into all of them is
optional. A user code in a location can be changed or deleted at anytime you like.
1) Enter your [MASTER CODE] and validate by [ ] [ ]
MASTER CODE
!
The
PROGRAM
2) Enter the user code location [11-18] you wish to deleted its user code and validate by [#]
USER CODE LOCATION
!
The user code in that location is deleted.
!
If the request is rejected, 5 beeps will be generated. Try again.
3) Exit the programming mode by pushing [ ] [ ]
!
System is back to operation mode.
CHANGE A TELEPHONE NUMBER IN AUTO-DIALER
The telephone numbers in both communicator and auto dialer can be changed or deleted if
required. The telephone number entry for communicator is usually handled by the installer or by
the technician of the monitor station. Details are described in the INSTALLATION SECTION,
programming locations 50-51.
The telephone numbers that you put in the auto dialer are usually the numbers of your friends,
relatives, your home/office phone, and even your portable phone or pager, you may change the
numbers from time to time. The 4 telephone numbers are stored at locations 60-63.
1) Enter your [MASTE CODE] and validate by [ ] [ ]
MASTER CODE
!
The
PROGRAM
2) Enter the telephone location [60-63] you wish to change its telephone number, key in
the message form [0 or 1] required, enter the new [TELEPHONE NUMBER] and validate
by [#].
TELEPHONE LOCATION
HA-266
HA-266
light comes ON.
#
light comes ON.
1
TELEPHONE NUMBER
NEW
CHANGE AND DELETE
#
67