If problems occur, the product shuts itself off automatically.
The display will show the reason (see below).
MESSAGE
PROBLEM
A01 burning pot
displays when the combustion
dirty
air intake is below the set level
displays when the logic board
A02
is not detecting the right smoke
fan speed
displays when the thermocouple
detects a smoke temperature
A03
lower than the set value and
interprets this as the absence of
flame
displays when ignition times out
A04
unsuccessfully
Shutdown due to air flow rate
A05
sensor breakage
displays when the logic board
determines that the smoke
A06
temperature probe is broken or
disconnected

TROUBLESHOOTING

15:36
14.9
°
C
off
T
M
A01
BURNING POT DIRTY
SOLUTION
Check that the combustion chamber door is closed
Check the regular maintenance of the stove
Check that smoke discharge and combustion air
ducts are clean.
Contact the technician
Check that there are pellets in the tank
Check that the water temperature has not increased
due to the closure of a valve (call a technician)
Contact the technician
There are two possibilities:
NO flame:
• Check that the burning pot is seated properly and clean
• Check that there are pellets in the tank and burning pot
• Try switching it on with a solid ecological igniter (contact
the technician beforehand and follow the instructions of
the igniter supplier very carefully).
The operation must be regarded purely as a trial under the
technician's guidance
Contact the technician
Contact the technician