Troubleshooting - EdilKamin VYDA2 AIR TIGHT C Installation, Use And Maintenance Manual

Hide thumbs Also See for VYDA2 AIR TIGHT C:
Table of Contents

Advertisement

If problems occur, the product shuts itself off automatically.
The display will show the reason (see below).
Do not disconnect from the power supply.
To start the appliance up again, allow the shutdown procedure to complete, then press
the ON/OFF button on the remote control or the simplified ignition button. Keep pressed till
"UNLOCK ?" will appear. Release then the key pressing it back again for a long time.
Before starting the product up again, check the reason for the shutdown and CLEAN THE
BURNING POT.
The product is equipped with a safety valve but, if the burning pot is not cleaned regularly
as explained above, ignition may involve a small detonation. If white smoke forms in the
combustion chamber for a long time, disconnect the mains supply and wait 30 minutes
before opening the door and emptying out the burning pot.
SHUTDOWN MESSAGES AND THEIR SOLUTIONS:
MESSAGE
PROBLEM
displays when the combustion
H01
air intake is below the set level
displays when the logic board
H02
is not detecting the right fumes
fan speed
displays when the thermocouple
detects a fume temperature
H03
lower than the set value and
interprets this as the absence of
flame
displays when ignition times out
H04
unsuccessfully
Shutdown due to air flow rate
H05
sensor breakage
displays when the logic board
determines
H06
thermocouple
disconnected

TROUBLESHOOTING

SOLUTION
Check that the combustion chamber door is closed
Check the regular maintenance of the stove
Check that smoke discharge and combustion air
ducts are clean
Contact the technician
Check that there are pellets in the tank
Contact the technician
Check that the tank is closed*
There are two possibilities:
NO flame:
Check that the burning pot is seated properly and is
clean
Check that there are pellets in the tank and burning
pot
Use a piece of solid paraffin to light the stove (contact
the technician first)
Flame present:
Contact the technician
Contact the technician
that
the
fumes
Contact the technician
is
broken
or
USER/INSTALLER
35

Advertisement