Download Print this page

Troubleshooting - EdilKamin SLIDE Manual

Advertisement

If problems occur, the stove shuts itself off automatically.
The display will show the reason (see below).
DO NOT disconnect the electrical power supply.
To start the product up again, allow the shutdown procedure to complete, then press the
remote control's ON/OFF button or the simplifi ed ignition button.
Before starting the product up again, check the reason for the shutdown and CLEAN THE
GRATE.
The product is equipped with a safety valve but, if the grate is not cleaned regularly as
explained above, ignition may involve a small detonation. If white smoke forms in the
combustion chamber for a long time, disconnect the mains supply and wait 30 minutes
before opening the door and emptying out the grate.
SHUTDOWN MESSAGES AND THEIR SOLUTIONS:
MESSAGE
H01
H02
28
H03
H04
H05
H06

TROUBLESHOOTING

PROBLEM
displays when the combustion
air intake is below the set level
displays when the logic board
is not detecting the right fumes
fan speed
displays when the thermocou-
ple detects a fume temperature
lower than the set value and in-
terprets this as the absence of
fl ame
displays when ignition times out
unsuccessfully
NOT available on this model
displays when the logic board
determines that the fumes ther-
mocouple is broken or discon-
nected
SOLUTION
• Check that the hearth door is closed
• Check that the stove, exhaust and combustion air duct
are clean.
Contact the technician
Check that there are pellets in the tank
Contact the technician
There are two possibilities:
NO FLAME PRESENT
• Check that the grate is seated properly and clean
• Check that there are pellets in the tank and grate
• Use a bit of solid paraffi n to ignite the stove (contact the
technician fi rst)
FLAME PRESENT
• Contact the technician
Contact the technician