TROUBLESHOOTING

PROBLEM
mimic panel off
remote control not working properly
outlet air not hot
no flame appears (remember that
the flame appears 5 minutes after
pressing the on/off key)
ignition failure
the ignition/shutdown process does
not start at the desired time
The channelling varies alone
Error rtc-dr displayed on the
synoptic panel
Chimneys and smoke ducts connected to solid fuel burning equipment must be swept once a year (check whether
specific regulations apply in your country). Lack of regular controls and cleaning increases the risk of fire in the
chimney. Should a fire occur proceed as follows:
do not extinguish with water,
empty the pellet tank,
consult specialised personnel before restarting the machine after the incident.

POSSIBLE CAUSES OF SHUTDOWN

If necessary the stove goes into arrest (that is to say the shutdown procedure starts), and the cause is displayed on the
screen.
1)
Check/Air flow: shutdown due to absence of depression in the combustion chamber
2)
Check/Expulsi: shutdown due to fault in the smoke expulsion motor revolution sensor
3)
Stop/fire: shutdown due to fall in smoke temperature
4)
BloccoAF/No start: shutdown due to incorrect smoke temperature during ignition
5)
Black-out: shutdown due to lack of electric power
6)
Broken/TC: shutdown due to faulty or disconnected thermocouple
7)
OverTemp/exit: shutdown due to maximum smoke temperature exceeded
8)
STOP FANFRONT: shutdown due to an anomaly in the front fan
9)
STOP FANCNLZ: shutdown due to an anomaly in the channelling fan
The warning is displayed until the ON/OFF key is pressed on the panel.
Do not restart the stove until the cause of shutdown has been removed.
To restart the stove in the event of an arrest let the shutdown procedure run its course (10 minutes marked by a beep)
then press the ON/OFF key.
Never unplug the stove whilst it is shutting down after an arrest.
It is important to report the warning displayed on the panel to the dealer.
NOTE
It is normal for air to be discharged from the right hand side of the upper front grate (looking at the stove face on).
Whereas it is discharged from the left hand side of the lower grate (when ducting is NOT enabled).
03/05/2011
CAUSE
no mains supply
too far way from the stove
remote control battery is flat
too much soot in the heat exchanger
the screw feeder has not been filled
build up of unburnt material in
combustion chamber
incorrect setting of:
current time
program activation
program activation on that day
the backup battery inside the
control board is flat
45
16.36
Pagina 46
SOLUTIONS
check that the power supply cable is
connected check the fuse (on the
power supply socket, Page 31)
ove nearer to the stove
check and change if necessary
clean the heat exchanger from inside
the firebox using the relevant rods
(see Page 47)
fill the screw feeder (see paragraph
on ignition, Page 38)
clean the combustion chamber
check according to the instructions
Verify the channelling scheduled timer
replace the backup battery