Profinet-Specific Parameter List - GE AF-650 GP PROFINET Operating Instructions Manual

Table of Contents

Advertisement

Parameters

8.4 PROFINET-specific Parameter List

Parameter
O-01 Control Site
O-02 Control Word Source
O-03 Control Word Timeout Time
O-04 Control Word Timeout Function
O-05 End-of-Timeout Function
O-06 Reset Control Word Timeout
O-07 Diagnosis Trigger
O-10 Control Word Profile
O-13 Configurable Status Word STW
O-50 Coasting Select
O-51 Quick Stop Select
O-52 DC Brake Select
O-53 Start Select
O-54 Reversing Select
O-55 Set-up Select
O-56 Preset Reference Select
8
8
O-90 Bus Jog 1 Speed
O-91 Bus Jog 2 Speed
PB-15 PCD Write Configuration
PB-16 PCD Read Configuration
PB-22 Telegram Selection
PB-23 Parameters for Signals
PB-27 Parameter Edit
PB-28 Process Control
PB-44 Fault Message Counter
PB-45 Fault Code
PB-47 Fault Number
PB-52 Fault Situation Counter
PB-53 Profibus Warning Word
PB-64 Device Identification
PB-65 Profile Number
PB-70 Edit Set-up
PB-71 Profibus Save Data Values
PB-72 ProfibusDriveReset
PB-80 Defined Parameters (1)
PB-81 Defined Parameters (2)
PB-82 Defined Parameters (3)
PB-83 Defined Parameters (4)
PB-90 Changed Parameters (1)
PB-91 Changed Parameters (2)
PB-92 Changed Parameters (3)
PB-93 Changed parameters (4)
EN-00 IP Address Assignment
EN-01 IP Address
EN-02 Subnet Mask
EN-03 Default Gateway
EN-04 DHCP Server
EN-05 Lease Expires
42
PROFINET Operating Instruction
Default value
Range
Dig. & ctrl. word [0]
[0 - 2]
Drive RS485 [0]
[0 - 4]
1
0.1-18000
Off [0]
[0 - 10]
Hold set-up [0]
[0 - 1]
Do not reset [0]
[0 - 1]
Disable [0]
[0 - 3]
GE Drive profile [0]
[0 - x]
*Logic OR [3]
[0 - 3]
*Logic OR [3]
[0 - 3]
*Logic OR [3]
[0 - 3]
*Logic OR [3]
[0 - 3]
*Logic OR [3]
[0 - 3]
*Logic OR [3]
[0 - 3]
*Logic OR [3]
[0 - 3]
0 - F-17 Motor Speed High
100 rpm
Limit [RPM]
0 - F-17 Motor Speed High
200 rpm
Limit [RPM]
-
-
-
-
-
[0 - 108]
-
0 - 573
Enabled [1]
[0 - 1]
Enable cyclic master [1]
[0 - 1]
0
[0 - 8]
0
-
0
-
0
0 - 1000
0
16 bits
0
[0 - 10]
0
8 bits
Active set-up [9]
[0 - 9]
Off [0]
[0 - 2]
No action [0]
[0 - 2]
-
0-115
0-115
-
0-115
-
0-115
-
0-115
-
0-115
-
0-115
-
0-115
0.0.0.0
0 - 255
0.0.0.0
0 - 255
0.0.0.0
0 - 255
0.0.0.0
0 - 255
0.0.0.0
0 - 255
00:00:00:00
-
Conver-
Data type
sion index
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
67
Uint16
67
Uint16
-
Uint16
-
Uint16
-
Uint8
-
Uint16
-
Uint16
-
Uint16
0
Uint16
-
Uint16
-
Uint16
0
Uint16
0
V2
0
Uint16
0
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
-
Unsigned 8
-
Oct. string 4
-
Oct. string 4
-
Oct. string 4-
-
Oct. string 4
-
Time diff. w/date