O-90 Bus Jog 1 Speed
Range:
Function:
100 RPM
[0 - par. F-17
Enter the jog speed. This is a fixed
*
RPM]
jog speed activated via the serial
port or network option.
O-91 Bus Jog 2 Speed
Range:
Function:
200 RPM
[0 - par. F-17
Enter the jog speed. This is a fixed
*
RPM]
jog speed activated via the serial
port or network option.

8.2 Parameter Group PB-## PROFIdrive

PB-15 PCD Write Configuration
Array [10]
Option: Function:
Select the parameters to be assigned to PCD 3 to 10 of
the messages. The number of available PCDs depends on
the telegram type. The values in PCD 3 to 10 will then be
written to the selected parameters as data values. Alterna-
tively, specify a standard Profibus message in
PB-22 Telegram Selection.
PB-16 PCD Read Configuration
Array [10]
Option: Function:
Select the parameters to be assigned to PCD 3 to 10 of
the messages. The number of available PCDs depends on
the telegram type. PCDs 3 to 10 contain the actual data
values of the selected parameters. For standard Profibus
message, see PB-22 Telegram Selection.
PB-22 Telegram Selection
Option:
Function:
Select a standard Profibus telegram
configuration for the frequency
converter, as an alternative to using
the freely configurable telegrams in
PB-15 PCD Write Configuration and
PB-16 PCD Read Configuration.
[1]
Standard telegram 1
[101]
PPO 1
[102]
PPO 2
[103]
PPO 3
[104]
PPO 4
[105]
PPO 5
[106]
PPO 6
[107]
PPO 7
[108]
PPO 8
*
[200]
Custom telegram 1
[202]
Custom telegram 3
PROFINET Operating Instruction
PB-23 Parameters for Signals
Array [1000]
Option: Function:
PB-27 Parameter Edit
Option:
[0]
Disabled Disables editing via PROFINET.
[1]
Enabled Enables editing via PROFINET.
*
PB-28 Process Control
Option:
[0]
Disable
[1]
Enable
*
cyclic
master
PB-53 Profibus Warning Word
Range:
0 N/A
*
Read only
This parameter contains a list of signals available for
selection in PB-15 PCD Write Configuration and PB-16 PCD
Read Configuration.
Function:
Parameters can be edited via PROFINET, the
standard RS485 interface, or the keypad.
Function:
Process control (setting of Control Word, speed
reference, and process data) is possible via either
PROFINET or standard Network but not both
simultaneously. Local control is always possible
via the keypad. Control via process control is
possible via either terminals or Network
depending on the settings in O-50 Coasting Select
to O-56 Preset Reference Select.
Disables process control via PROFINET, and
enables process control via standard Network or
PROFINET IO-Supervisor.
Enables process control via IO Controller, and
disables process control via standard Network or
PROFINET IO-Supervisor..
Function:
[0 - 65535 N/A] This parameter displays PROFINET
communication warnings. Please refer
to the PROFINET Operating Instructions
for further information.