4-2 TRANSMIT ADJUSTMENTS

ADJUSTMENT
FREQUENCY
1
-Verification-
TRANSMIT
1
OUTPUT POWER
-Adjustment-
(Extra High)
(High)
2
(Middle)
3
(Low)
4
(Extra High)
5
6
7
(High)
8
9
10
(Middle)
11
12
13
(Low)
14
15
16
ADJUSTMENT ITEM
DISPLAY
• Connect the RF power meter or
• Loosely couple the frequency
• Transmitting
• Connect the RF power meter to the
• While transmitting, adjust the
• Transmitting
• Receiving
SETTING CONDITION
the dummy load to the antenna
connector.
counter to the antenna connector.
antenna connector.
connected DC power supply
voltage to 7.5 V.
4-4
OPERATION
146.000 MHz ±365 Hz
(If out of the specified range,
adjust the frequency by [VOL],
then push [# ENT]•[
Set the transmit output power to
7.0 W ±0.2 W by [VOL], then push
[# ENT]•[
].
Note the adjusted value as the
reference value A.
Set the transmit output power to
5.5 W ±0.2 W by [VOL], then push
[# ENT]•[
].
Note the adjusted value as the
reference value B.
Set the transmit output power to
2.5 W ±0.2 W by [VOL], then push
[# ENT]•[
].
Note the adjusted value as the
reference value C.
Set the transmit output power to
0.5 W ±0.1 W by [VOL], then push
[# ENT]•[
].
Note the adjusted value as the
reference value D.
Set the adjustment value to the
value that add 2 to the reference
value B, then push [# ENT]•[
Set the adjustment value to the
value that add 6 to the reference
value A, then push [# ENT]•[
Set the adjustment value to the
value that add 10 to the reference
value B, then push [# ENT]•[
Set the adjustment value to the
value that add 2 to the reference
value B, then push [# ENT]•[
Set the adjustment value to
the value that subtract 2 to the
reference value B, then push
[# ENT]•[
].
Set the adjustment value to the
value that add 10 to the reference
value B, then push [# ENT]•[
Set the adjustment value to the
reference value C, then push
[# ENT]•[
].
Set the adjustment value to the
value that add 1 to the reference
value C, then push [# ENT]•[
Set the adjustment value to the
value that add 13 to the reference
value C, then push [# ENT]•[
Set the adjustment value to the
reference value D, then push
[# ENT]•[
].
Set the adjustment value to the
value that add 2 to the reference
value D, then push [# ENT]•[
Set the adjustment value to the
value that add 10 to the reference
value D, then push [# ENT]•[
].)
].
].
].
].
].
].
].
].
].

Advertisement