ADDING CABLE LINES
Follow these instructions to add cable lines:
• Strip the cable by 50-60mm with a wire stripper, then strip the rubber hose to reveal a 20-30mm copper wire.
• Tighten two cable lines with the same colour into a spiral shape so as to guarantee close connection.
• Tightly wind and cover the cable with the electrical insulating tape from the 15-20mm core cord.
• Wrap the cable that is covered with the electrical insulating tape with a waterproof adhesive tape from the 20-30mm core cord. The waterproof adhesive
tape should be 10mm longer than the electrical insulating tape at both ends. Before the wrapping, the waterproof tape should be stretched out 1-fold its
length and follow the normal use.
• Wrap the cable that is wrapped with the waterproof adhesive tape with the electrical insulating tape.
• Wrap the cable that is wrapped with the electrical insulating tape with the waterproof adhesive tape. The waterproof adhesive tape should be 10mm longer
than the electrical insulating tape at both ends. Before the wrapping, the waterproof tape should be stretched 1-fold its length and follow the normal use.
• Immerse the junction of the cable into the water for 12 hours. Test the insulation resistance of the cable with the 500V megohmmeter. The cold insulation
resistance should not be less than 50 MΩ.

USE INSTRUCTIONS

• The delivery pipe shall be matched to the water outlet (the specification shall be selected based on the performance parameter table). For example, the iron
wire or clamp can be used to connect with soft delivery pipes. The screwed joint can be used for steel delivery pipes for further reliable connection. Further,
the threading ropes are used at the handle in case of lifting in the water. The tied ropes of hoisting electric pump must be firm and durable. The cable lines
shall not be stretched but in a natural loose state.
• The cables cannot withstand being crushed and are not designed to be used as lifting ropes. Further, do not pull the cables randomly during operation so as
to avoid electrical shock caused by cable damage.