How To Test The Module Transmission Performance - ICP DAS USA I-7530 User Manual

Rs-232/can converter
Hide thumbs Also See for I-7530:
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
values, which are:
RS232:
CAN:
3.2

How to test the module transmission performance

The following procedure will guide you to learning how to
transmit/receive CAN messages to/from other devices/PCs by using the I-
7530 converter. Note that users can only employ this test function for the
system if they are using the default communication parameters for the
RS-232 as provided above.
1. Set the Init/Normal switch to the Normal position, which is found at the
back of the I-7530 module.
2. Connect the I-7530's CAN port into the CAN network, which must at
least have one CAN device on the network.
3. Supply the 10~30 volts DC source into the I-7530 module through the
power terminal.
4. The ON LED on the I-7530 module will be turned on. That means the I-
7530 is working in the operation mode.
5. Run the I-7530 Utility software after there is a wire connection as
shown in Section 1.5.
6. Click the "Settings..." icon on the tool bar in the I-7530 Utility to
configure the PC COM port, which will be used to connect to the COM
port of the I-7530.
I-7530 RS-232/CAN Converter User's Manual (Version 1.0,Aug/2004, 7PH-021-01) ------------- 15
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
RS-232 Baudrate = 115200
Data Bit
Stop Bit
Parity
Add Checksum
Error Response
CAN Specification = 2.0A
CAN bus Baudrate = 125K
Acceptance Code = 00000000
Acceptance Mask = 00000000
= 8
= 1
= None
= No
= No