How To Configure The Module Parameters - ICP DAS USA I-7530 User Manual

Rs-232/can converter
Hide thumbs Also See for I-7530:
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
3.1

How to configure the module parameters

The following procedure will guide you on how to configure the
communication parameters for the CAN and RS-232 interface. The
configuration steps are depicted as below:
1. Set the Init/Normal switch to the Init position, which is located at the
back of the I-7530 module.
2. Connect the power source (the 10~30 DC volts) into the I-7530 module.
3. The I-7530 module's ON LED will flash approximately once per second.
That means the I-7530 module is working in the configuration mode.
4. The user must run the I-7530's Utility software after they have made a
wire connection between the PC and the I-7530 via the COM port.
5. Click the "Settings..." icon on the I-7530 Utility tool bar in order to select
which PC COM port will be used to connect to the I-7530 COM port, as
shown in the following figure. Then click the "OK" button.
I-7530 RS-232/CAN Converter User's Manual (Version 1.0,Aug/2004, 7PH-021-01) ------------- 13
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Figure 11: I-7530 Utility