Download Print this page

Ricoh Streamline NX Technical Bulletin page 7

Advertisement

Reissued: 28-Jun-16
Model:
Streamline NX
Encryption of parameters in request data between SPM-E and SPM-S/Client Tool.
(Parameters: User name, Job ID, and Request time)
- Windows 10 support
- Java 8 support
- VMWare vSphere v6.0 support
- HotSpot Enterprise v3 linkage support (v2.6.0 and v2.5.1)
- SFM plug-in activation change from GMP to eDC-i
- Client Tool
From Client Tool v1.3.0, when "Force Value" is applied using "Import Configuration"
button, the value can be changed in "Administrator mode" by using the import function.
- SPM-E(+HDD)
SPM-E(+HDD) v2.6.0 has only been verified to support 07S-14S (GW or GW+).
Function added after SLNX v2.2.1 can be not used in SPM-E(+HDD) v2.6.0. For instance
a delegation function of Client tool, billing code cannot be used.
-Administration Manager:
The ADM installer will not overwrite the keystore and cacerts files if the same file names
exist in the specified folder.
Fixed:
- Report Generator:
- The Quota Report is not generated during a designated week/month but between the
"Reset User Point" timings for both the start and end time of the Quota period.
- Line breaks in the message confirmation dialogue differs between report deletion and
report schedule deletion.
-The value of the decimal part of a cost calculation result will be incorrect if the integer part
consists of 7 or more digits.
-When an upgrade installation to either v2.4.x or v2.5.x is performed, the settings for
disabling SSL 3.0 will not work in RG.
-An error will occur if the "Portecle.bat" file is executed via "Run as Administrator".
-Administration Manager:
-When using the "Batch Configuration function" with SLNX v2.5.x, an unnecessary waiting
time occurs between each template application.
-Authentication and Accounting Manager:
-The Quota Group Administrator cannot enable Usage Limit Management in the user
properties when additional points are given to the user at the same time.
-If round robin DNS is used, AAM-S caches the IP addresses of the KDCs it cannot
successfully connect to. AAM-S will not try connecting to those cached IP addresses until
AAM-S fails to connect to all other KDCs.
-"Next Execution Time" for User Point Reset in Quota Group Management is not displayed
correctly.
-When a print job's document name exceeds 256 characters, the recode is not registered
in the AAM-S job logs.
T
B
echnical
ulletin
Date:
5-Apr-12
PAGE: 7/26
No
.: RD639001o

Advertisement

loading