  • Page 1 A15.1018 Polarizing Microscope, Transmit Light Instruction Manual To ensure the safety and obtain satisfactory performance, please study this instruction manual thoroughly be fore start to use the instrument.
  • Page 2: Table Of Contents

    CONTENTS CONTENTS ………………………………………………………… USER NOTIECE …………………………………………………… NOMENCLATURE 1、 ………………………………………………… ASSEMBLY 2、 ……………………………………………………………… 2-1.Assembly Diagram …………………………………………………… 2-2.Detailed Assembly Procedure……………………………………… USING THE CONTROLS 3、 …………………………………………… POLARIZED LIGHT OBSERVATION 4、 ……………………… SPECIFICATIONS 5、 …………………………………………………...
  • Page 3: User Notiece

    USER NOTICE Ⅰ.Safety Precautions 1. Carefully open the box, avoid the accessories, like lens, dropping to ground and being damaged. 2. Do keep the instrument out of direct sunlight, high temperature or humidity, dusty and easy shaking environment. Make sure the stage is smooth, horizontal and firm enough.
  • Page 4 wipe up the moisture. Do not disassemble any parts of the microscope. That will affect the function or decline the performance of the microscope. Place the instrument in a cool, dry position. After using the microscope, remember to cover it with dust helmet. Do wait for the lamp house cooling completely before cover.
  • Page 5: 1、 Nomenclature

    1. NOMENCLATURE Video port Eyepiece Trinocular viewing head Lamp housing Bertrand lens unit Reflected illumination system Objective Main body Revolving round stage...
  • Page 6: 2、 Assembly

    2.Assembly Assembly Diagram The diagram below shows how to assemble the various components. The numbers indicate the order of assembly.  When assembling the components, make sure that all parts are free of dust and dirt, and avoid scratching any parts or touching glass surfaces. ...
  • Page 7: 2-2.Detailed Assembly Procedure

    2-2 Detailed Assembly Procedure 2-2-1 Installing the Polarizing Stage Support Device ② 1. Before installing the device, be sure to ① adjust the coarse focus knob①. Make the guide board② (see figure 1) down to the lowest position, so you can install the mechanical stage support device easily.
  • Page 8 ⑦ 2-2-3 Installing the Objective 1. Adjusting the coarse focus knob until the support device of the mechanical stage reach its low limit position. 2. Insert the 10X objective into the primary hole (which without centering holes on its sides) on the nosepiece, then push the nosepiece clockwise and install other objectives by the sequence of low to high magnification ( figure 5).
  • Page 9 2-2-7 Installing the Video Port (Fig.7) Insert the video port ⑦into the trinocular viewing head, then screw down the bolt⑧ to fix it. 2-2-8 Installing the Eyepiece (Fig.7) Insert the eyepiece into the eyepiece tube until they are against each other. 2-2-9 Installing the lamp house ①...
  • Page 10: Using The Controls

    3. USING THE CONTROLS Analyzer 检偏器 Bertrand lens unit 勃氏镜转盘 Bertrand lens Polarizer focusing plate Compensator clamping knob Compensator Polarizing ruler Polarizing adjustment knob 调节旋钮 Vernier scale Stage rotation 平台支紧螺钉 clamping knob Polarizer clamping knob Polarizer clamping Polarizer rotation ring 起偏器转环...
  • Page 11 Using controls 3-2-1 Stage Rotation When the stage rotation clamping knob ① is loosened, the stage can be rotated horizontally through 360°. 3-2-2 Using 45° Click Stop Lever When the 45° click stop lever② is ① moved toward the observer, and the stage is moved from this position to Fig.10 the first click-stop position, the specimen...
  • Page 12: Polarized Light Observation

    4. Polarized Light Observation 4-1 Adjustments before observation 4-1-1 Focus ② Use the 10×objective to focus. To avoid the ① objective touch with the specimen, you should raise the mechanical stage and let the specimen close to the objective, then slowly separating them to focus.
  • Page 13 3. Moving the specimen only, move a new specimen detail into the cross line center. 4. Repeat steps 2 and 3 several times until the center of the stage rotation is in the center of the cross lines, i.e., when rotating the stage, the specimen stays in the center of the cross lines. This concludes centering of the optical axis for the 10X objective, which will act as the reference objective.
  • Page 14: Specifications

    Note:If the periphery of the conoscopic image is dark, move the condenser vertically to find the position where the periphery is brightest. 5.Technical Specifications 1. Main specifications 1.system:Infinite system 2.polarized objective(plan) Magnification Numerical Thickness of Working Work illumination aperture cover distance type slip(mm)
  • Page 15 2. Configuration Table item Specifications Main frame ● ● ● Rotatable stage ● ● ● Main Body polarized ruler ○ ○ ○ Condenser bracket ● ● ● Viewing Trinocular tube ● ● ● system polarizer ● ● ● Analyzer Polarizing ●...
  • Page 16 User manual ● ● ● ● ● ● Packing list ● ● ● Package ● ● ●...