Danfoss VLT Micro Drive PK18 Design Manual page 88

Table of Contents

Advertisement

Specifications
9.1.2 Mains Supply 3 x 200 - 240 V AC
Normal overload 150% for 1 minute
Frequency converter
Typical Shaft Output [kW]
Typical Shaft Output [HP]
IP 20
Output current
Max. input current
Table 9.2 Mains Supply 3 x 200 - 240 V AC
1.
At rated load conditions.
VLT Micro Drive Design Guide
Continuous (3 x 200-240 V) [A]
Intermittent (3 x 200-240 V) [A]
Max. cable size:
(mains, motor) [mm
2
/AWG]
Continuous (3 x 200-240 V) [A]
Intermittent (3 x 200-240 V) [A]
Max.mains fuses [A]
Environment
Estimated power loss [W], Best case/
1)
Typical
Weight enclosure IP20 [kg]
Efficiency [%], Best case/Typical
1)
®
MG02K102 - VLT
is a registered Danfoss trademark
PK25
PK37
PK75
0.25
0.37
0.75
0.33
0.5
1
Frame M1 Frame M1 Frame M1 Frame M2 Frame M3 Frame M3
1.5
2.2
4.2
2.3
3.3
6.3
4/10
2.4
3.5
6.7
3.2
4.6
8.3
See Section Fuses
14.0/
19.0/
31.5/
20.0
24.0
39.5
1.1
1.1
1.1
96.4/
96.7/
97.1/
94.9
95.8
96.3
P1K5
P2K2
P3K7
1.5
2.2
3.7
2
3
5
6.8
9.6
15.2
10.2
14.4
22.8
10.9
15.4
24.3
14.4
23.4
35.3
51.0/
72.0/
115.0/
57.0
77.1
122.8
1.6
3.0
3.0
97.4/
97.2/
97.3/
97.2
97.4
97.4
87
9
9

Advertisement