8.2.

Operation procedure

Using "A1" program, operate in the following procedures.
(1) Exchange it for a use hand from a hand for tool setting.
For example change it to the following hand.
(2) Set the controller mode to "MANUAL". Set the T/B to "ENABLE".
O/P
(3) Press one of the keys (example, [EXE] key) while the <TITLE> screen is displayed. The <MENU> screen
will appear.
MELFA CR75x-D
RH-3FH5515-D
COPYRIGHT (C) 2015 MITSUBISHI
ELECTRIC CORPORATION ALL RIGHTS
RESERVED
(4) Select "1. FILE /EDIT" screen on the <MENU> screen.
<MENU>
1.FILE/EDIT
3.PARAM
5.SET/INIT
123
(5) Press the arrow key, combine the cursor with the program name "A1" and press the [EXE] key. Display the
<program edit> screen.
<FILE/EDIT>
1
15-02-03 17:06:39 12345
A1
15-02-03 17:06:39 12345
CM1
15-02-03 17:06:39 12345
EDIT
POSI
123
Ver. S6
2.RUN
4.ORIGIN/BRK
CLOSE
NEW
COPY
T/B
↑上:DISABLE
↓下:ENABLE
Lamp lighting
T/B rear
<MENU>
1.FILE/EDIT
2.RUN
3.PARAM
4.ORIGIN/BRK
5.SET/INIT
123
<FILE/EDIT>
1
15-02-03 17:06:39 12345
A1
15-02-03 17:06:39 12345
CM1
15-02-03 17:06:39 12345
EDIT
POSI
NEW
123
< PROGRAM > A1
1'################################
2 '# Conveyor circular arc tracking
3 '# Program name : A1.prg
4 '# Date/Version : 2015.01.28 / 1.0
EDIT
POSI
NEW
123
8 Teaching Operation("A1" Program)
CLOSE
COPY
COPY
Operation procedure 8-47