2.7 Setting the Bus-Clock Frequency
The HS-2601 provides all necessary by jumper setting in using
Bus-Clock frequency as the system bus clocking with JP2 setting as
following:
Bus-Clock Frequency Setting of JP2 :
Bus-Clock Frequency
*66MHz
100MHz
2.8 System Memory DRAM
The HS-2601 provides a single size SDRAM memory by one piece
SODIMM socket request the access time should meet PC-100
standard. The maximum capacity of the on board memory is
256MB.
2.9 Setting the Flat Panel Voltage
The HS-2601 provides a setting for the selection of the working
voltage of individual flat panel by JP4 setting as following:
Flat Panel Voltage Selecting of JP4:
Panel's Working Voltage
5.0 V
* 3.3 V
Please contact with your flat panel supplier for make sure a correct
Panel's Working Voltage. Any mistake will cause defect to your flat
panel.
12
JP2
ON
OFF
JP4
1-2
2-3