Auto Shut-Down - Hitachi ZAXIS 130-6N Operator's Manual

Hydraulic excavator
Table of Contents

Advertisement

Auto Shut-Down

d
WARNING: This function automatically stops
the engine. Take extra care on the work and work
environment when using this function.
When the auto shut-down function is turned ON, the engine
automatically stops after the preset time at the state in which
the pilot control shut-off lever is pulled. 30 seconds before the
engine stop, monitor screen (2) displays "Engine Shut-Down
Soon." message and indicator (1) starts flashing. Also the
buzzer sounds. The buzzer sounds once at 30 seconds before,
and continuously sounds from 15 seconds. The engine speed
decreases to the idling speed, and then stops after 15 seconds.
When the pilot control shut-off lever is pushed down before
stopping the engine, the auto shut-down is disabled and the
engine will not stop.
IMPORTANT: Check whether the status of auto shut-
down indicator (1) is ON or OFF. If indicator (1) is ON,
the auto shut-down function will be activated.
Operating Condition
 The engine is running.
 The pilot control shut-off lever is in the LOCK position.
 Coolant and hydraulic oil temperature are not high.
 The aftertreatment device is not in the process of manual
regeneration.
IMPORTANT:
 When the engine is stopped by the auto shut-down
function, turn the key switch to ACC or OFF once and
then turn it to START to restart the engine. Turn the
key switch OFF after auto shut-down when leaving
the machine for long period of time. Do not leave the
machine after auto shut-down. Failure to do so may
discharge the batteries.
 When the key switch is turned to the OFF position
while the auto shut-down function is ON, the setting
will be reset. When required to keep the setting,
consult your authorized dealer.
OPERATING THE MACHINE
5-7
1
2
MDC1-01-146EN
MDC1-01-286

Advertisement

Table of Contents
loading

Table of Contents