3. At this time, do not remove the inner element.
IMPORTANT: Do not hit or strike outer element (1)
against another object to clean the element.
4. Allow compressed air pressure [less than 0.69 MPa (7 kgf/
cm
)] to blow out of the inside of outer element (1) to
2
clean the element. After that, blow compressed air along
the pleats, and then blow out from the inside. When
blowing compressed air, be sure to keep the air nozzle
50 mm or away from the element.
5. After cleaning is complete, be sure to check outer
element (1) for any damage such as holes or wear of filter
paper. If any damage is found, replace the element with
a new one.
6. Press outer element (1) into the air cleaner body
straightly by hand. Ensure that outer element (1) is
properly installed by pushing its bottom edge.
7. Install cover and tighten clamps (2).
8. In case the air filter restriction indicator lights soon after
cleaning outer element (1) even if it has been cleaned
less than 6 times, replace both outer and inner elements
with new ones.
IMPORTANT: Do not install outer element (1) and/or the
cover forcibly when installing the clamps. Doing so
may result in deformation of clamps (2), element, and/
or cover.
MAINTENANCE
ZX210-6N, 210LC-6N, 250LC-6N, 300LC-6N, 350LC-6N, 380LC-6N
MJAE-07-059
ZX210-6N, 210LC-6N, 250LC-6N, 300LC-6N, 350LC-6N, 380LC-6N
7-72
ZX130-6N, 160LC-6N, 180LC-6N
1
ZX130-6N, 160LC-6N, 180LC-6N
2
1
2
MDAA-07-079
M1U1-07-080
M1U1-07-027
M1U1-07-028