Auto Shut-Down

d
WARNING: This function automatically stops
the engine. Take extra care on the work and work
environment when using this function.
The auto shut-down function can be set in this screen. The
engine automatically stops after the preset time at the state
in which the control shut-off lever is pulled. 30 seconds
before the engine stops, the monitor screen displays
remaining time to stop the engine and the indicator starts
flashing. The buzzer also sounds. The buzzer sounds once at
30 seconds before, intermittently sounds from 15 seconds.
The engine speed decreases to the idling speed, and then
stops after 15 seconds. When the control shut-off lever
is pushed or the engine control dial is operated before
stopping the engine, the auto shut-down is disabled and
the engine will not stop.
IMPORTANT: When the engine stops by the auto shut-
down function, turn the key switch to OFF once and
then turn it to START to restart the engine.
Auto Shut-Down Time Setting
1. Push menu switch (2) while displaying basic screen (1) to
display MENU (3).
2. Select Auto Shut-down (7) by pushing switch (4) or (5),
and then push set switch (6) to make the change.
3. Auto shut-down time (8) becomes changeable. Select
Time (8) by pushing switch (4) or (5).
Auto Shut-Down Time
OFF
3 min
5 min
10 min
15 min
OPERATOR'S STATION
3
1-29
2
3
7
4
5
6
ZX30U-5N, 35U-5N
MADG-01-099
8
4
5
ZX30U-5N, 35U-5N
MADG-01-101
1
MADH-01-009
7
4
5
6
ZX50U-5N, 60USB-5N
MADG-01-100
8
4
5
ZX50U-5N, 60USB-5N
MADG-01-102

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents