Auto Shut-Down

d
WARNING: This function automatically stops
the engine. Take extra care on the work and work
environment when using this function.
The auto shut-down function can be set in this screen. Set
the auto shut-down time and enable (ON) the function
beforehand. The engine automatically stops after the preset
time at the state in which the pilot control shut-off lever
is pulled. 30 seconds before the engine stop, the monitor
displays a message that engine will be stopped and the
indicator starts flashing. The buzzer also sounds. The buzzer
sounds once at 30 seconds before, and then continuously
sounds from 15 seconds. The engine speed decreases to the
idling speed, and then stops after 15 seconds. When the pilot
control shut-off lever is pushed before stopping the engine,
the auto shut-down is disabled and the engine will not stop.
IMPORTANT: When the engine stops by the auto shut-
down function, turn the key switch to ACC or OFF once
and then turn it to START to restart the engine. Turn
the key switch OFF after auto shut-down when leaving
the machine for long period of time. Do not leave the
machine after auto shut-down. Failure to do so may
discharge the batteries.

Auto Shut-Down: ON/OFF

1. Press selector knob (2) while displaying Basic Screen (1)
to display Main Menu screen (3).
2. Rotate selector knob (2) to highlight Setting Menu (4).
3. Press selector knob (2) to display Setting Menu screen
(5).
4. Rotate selector knob (2) to highlight Auto Shut-Down (6).
OPERATOR'S STATION
1-47
1
MDAA-01-001EN
2
MDCD-01-026
3
4
MDAA-01-114EN
5
6
MDAA-01-147EN