Hitachi ZAXIS 130-6N Operator's Manual page 301

Hydraulic excavator
Table of Contents

Advertisement

IMPORTANT: Install drainer (5) to drain valve (3) slowly.
Oil may exhaust in large quantities when suddenly
tightened.
8. Remove oil filler cap (2).
9. Remove cap (4) from oil pan drain valve (3). Install
drainer (5) to drain valve (3).
10. Screw drainer (5) into drain valve (3). Drain valve (3) will
be opened to drain oil.
11. Then, allow oil to drain through a clean cloth into a
container.
ZX130-6N, 160LC-6N, 180LC-6N,
210-6N, 210LC-6N, 250LC-6N
ZX300LC-6N, 350LC-6N, 380LC-6N : 60-liter (16 US gal)
12. After all oil has been drained, inspect the cloth for any
debris such as small pieces of metal.
13. Remove drainer (5). Install cap (4) to drain valve (3).
Oil Pan
Clean Cloth
Container
M104-07-010
MAINTENANCE
: 50-liter (13 US gal)
Oil
Oil
Screw
Oil
M1U1-07-002
5
M1U1-07-046
2
2
Oil Pan
3
5
2
250LC-6N, 300LC-6N, 350LC-6N, 380LC-6N
3, 4
7-35
ZX130-6N
ZX160LC-6N, 180LC-6N
ZX210-6N, 210LC-6N,
MDC1-07-070
MDC1-07-069
MDC1-07-023
M1U1-07-045