H2
1
Button for height calibration
H1
2
Altitude calibration key
Battery calibration
3
Press this key to calibrate the battery.
However, this should only be done after replacing the battery.
ESC
4
Press this key to return to the settings page or to save your entries.
Calibration of the stroke height
1. Set the mode selector switch to position 1
2. Lower the lifting fork completely
3. Press the H1 key and enter the value 0 in the pop-up window.
4. Confirm this value by pressing the Enter key.
5. Raise the lifting fork to 1.5m
6. Measure the actual distance from the floor to the bottom of the lifting fork with a tape measure or
another suitable measuring tool